Fig. 1
Roughing-in Dimensions
108mm-133mm
(4-1/4" to 5-1/4")
SUPPLY
DN 19mm
(3/4" I.P.S. For 3/4" Top Spud)
*CRITICAL
LEVEL
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver (For adjusting Supply Stop)
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
-C-L-
295mm
(11-1/2")
3/4" VACUUKM
BREAKER SHOWN
152mm
(6)
(Min.)
"
(152mm) minumim above fixture.
GENERAL DESCRIPTION:
FINISHED WALL
38mm-127mm
(1-1/2-5")
-C-L-
135mm
(13-1/2")
Right or Left Hand Installation
(Section 8)
See
Valve to Left Hand Installation.
Fig. 2
1
5
7
• Flush all water lines prior to operation (See Step 5). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
2
MANUAL FLUSH VALVE, 0.5 GPF
Exposed Flushometer
for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-operated
flush valve.
OPERATING PRESSURE:
Overall Range: 20-125 psi **
Recommended: 20 psi (flowing)-
80 psi (static)
FLOW REQUIREMENT:
10gpm (37.9 L/min).
**Water pressure over 80 psi is not
recommended with most
plumbing fixtures
for converting Flush
2
3
10'
4
6
9
10
M965360 REV. 1.9 (5/19)