Maintenance And Care; Storage; Disposal - AL-KO SUB 10000 DS Manual De Instrucciones

Ocultar thumbs Ver también para SUB 10000 DS:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Startup
Automatic mode
1. In automatic mode, set the adjustable foot to
position "U" (bottom) to achieve the greatest
possible feed rate.
2. Insert the mains plug into the plug socket.
Models with float switch
3. Switch the operation selection switch on the
mains switch to "AUTO" (Fig. G).
Models with level switch
4. Slide the level switch upwards to the desired
switch-on height (Fig. I).
➯ The pump switches on automatically at a
specific water level (switch-on height) by
the float switch and when the water level
falls to the switch-off height it switches off
again, see technical data Page 5
Manual operation mode
In manual mode, the water can be pumped away
to a very low level of residual water.
Minimum water level for commissioning: see tech-
nical data.
Pumping out to residual water level
CAUTION!
Monitor the pump continuously when
pumping out to the residual water level
and avoid the pump running dry. Shut
the pump down when the residual wa-
ter level has been reached by switching
the operation mode selector switch to
"AUTO". The pumps switch on again au-
tomatically when the switch-on height is
reached.
Set the adjustable foot to the "O" (top) position for
pumping out to the residual water level:
1. Remove the mains plug from the plug socket.
Models with float switch
2. Switch the operation selection switch on the
mains switch to "MAN" (Fig. G). The pump
switches on and starts to feed.
Models with level switch
3. Slide the level switch upwards to the "MAN"
position (Fig. I).
ADVICE
If the water drops below the residual wa-
ter level, the pump will draw air in. In this
case, the pump must be vented when
the water level rises and before using it
again.
467772_f

MAINTENANCE AND CARE

Cleaning the pump
ADVICE
After
conveying
swimming pool water or fluids that leave
a residue, the pump must be flushed out
with clear water.
1. Clean the suction slots on the suction foot if
necessary with clear water.
Removing/fitting the level switch
see Fig. H
1. Unscrew the fixing screw(2) and then first tip
the Level switch housing(1) upwards and then
tilt to the front.
2. Clean the float body (4) and guides (3).
3. Place the float body back in the guide.
4. Replace the housing float body and push
downwards.
5. Screw the fixing screw in.
Removing/fitting the adjustable foot
TWIN pumps
see Fig. F
1. Unscrew the engaging screws (7) and pull the
adjustable foot (6) out of the pump housing
(8).
2. Clean the adjustable foot and the pump hou-
sing.
3. Insert the adjustable foot in the pump housing,
align and screw the engaging screws back in
place.

STORAGE

ADVICE
In the event of a risk of frost, the system
must be drained completely.

DISPOSAL

Do not dispose of worn-out machines
or spent batteries (including recharge-
able batteries) in domestic waste!
The packaging, machine and accessories
are made from recyclable materials and
must be disposed of accordingly.
chlorine-containing
17
Tabla de contenido
loading

Tabla de contenido