Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts; Ordering Replacement Parts; Disposal And Recycling - Neptun NPHW-E 4100 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
priming can take up to 5 minutes at maximum
suction height.
The equipment will shut down when the cut-
out pressure of 3 bar is reached.
After a loss of pressure due to water con-
sumption the equipment will cut in again auto-
matically (cut-in pressure approx. 1.5 bar).

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
Inside the pressure tank is an expandable
water sack and an air compartment whose
maximum pressure should lie at approx. 1.5
bar. Pumping water into the water sack cau-
ses the sack to expand so that the pressure in
the air compartment rises to switch-off level. If
the air pressure is too low, you should raise it.
To do so, unscrew the plastic lid from the tank
and top up the pressure to the correct level
using a tyre pump with meter at the valve.
Important: Be sure to completely empty
the water bag first using the water drain
screw (3).
Replacing the mains cable: Important:
Disconnect the equipment from the power
supply! A defective mains cable may only be
Anl_NPHW_E_4100_SPK7.indb 15
Anl_NPHW_E_4100_SPK7.indb 15
GB
replaced by a qualified electrician.
There are no parts inside the equipment
which require additional maintenance.
8.2 Cleaning the coarse fi lter insert
Clean the coarse filter insert at regular inter-
vals, and replace it if necessary.
Remove the coarse filter screw (5) and coar-
se filter (7) together with the non-return valve
(8) (Figure 2).
Disassemble the coarse filter insert as shown
in figure 3.
Do not use abrasive cleaning agents or petrol
to clean the coarse filter and the non-return
valve.
Clean the coarse filter and the non-return val-
ve by tapping them on a flat surface. In cases
of stubborn dirt, first clean with soapy water,
then rinse with clear water and air-dry.
Assemble in reverse order.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
- 15 -