ATTACHED ACCESSORIES
No.
Name
Qty.
Remote control
1
(1)
Remote control cable
1
(2)
Screw
(M4 machine pitched
3
(3)
- 30mm)
Screw
(M4 self tapping
3
(4)
- 14mm)
1. SELECTING THE INSTALLATION LOCATION
Remote control
Upper case
Lower case
•
Allow suffi cient space around the remote control (1) as shown in
the illustration above.
•
Install in a place which is away from direct sunlight and high
humidity.
•
Install in a fl at surface to avoid warping of the remote control. If
installed to a wall with an uneven surface, damage to the LCD case
or operation problems may result.
•
Install in a place where the LCD can be easily seen for operation.
(Standard height from the fl oor is 1.2 to 1.5 meters.)
•
Avoid installing the remote control cable near refrigerant pipes or
drain pipes, else it will cause electrical shock or fi re.
2. INSTALLING THE REMOTE CONTROL UNIT TO THE WALL
Screw
driver
1. Remove the remote control (1) lower case.
(Insert a fl at-tipped screw driver or similar tool 2 to 3 mm into one
of the gaps at the bottom of the case, and twist to open. Refer to
the illustration above.)
Be careful not to damage the lower case.
2. Do not remove the protective tape which is affi xed to the upper
case circuit board when removing the remote control lower case.
3. Secure the lower case to an outlet box or wall. Refer to (A) or (B)
instructions below depending on your choice of cable installation.
4. Be sure to use only the screws provided.
5. Do not over tighten the screws, as it may result in damage to the
lower case.
Diagram
Remark
Length (15 m)
Installing the remote
control to an outlet
box (embedded cable)
Installing the remote
control to the wall
(exposed cable)
30mm or
more
30mm
30mm
or more
or more
Remote
control
lower case
120mm
or more
Upper case
Gaps
Lower case
Screw (3) or
Screw (4)
A. IF REMOTE CONTROL CABLE IS EMBEDDED
1. Embed an outlet box (JIS C 8336) into the wall. Outlet box may
be purchased separately.
Medium-sized square outlet
box (obtain locally) Part No.
DS3744 (Panasonic Co.,
Ltd.) or equivalent.
2. Secure the remote control
lower case to the outlet
box with the two accessory
screws (3).
Make sure that the lower
case is fl at against the wall
at this time, with no bending.
3. Pass the remote control
cable (2) into the box.
4. Route the remote control
cable (2) inside the lower case through rear feeding-out
direction.
5. Insert fi rmly the connector of remote control cable (2) to
connector (CON1) in the upper case circuit board. [Refer to the
illustration at below.]
6. Secure the remote control upper case to the lower case with the
tabs provided.
When the wall is hollow, please be sure to use the sleeve for remote control
cable to prevent dangers caused by mice biting the cable.
Remote control
cable (2)
Rear feeding-out
position
Tabs
Lower case
B. IF REMOTE CONTROL CABLE IS EXPOSED
1. Install the remote control lower case to the wall with the two
accessory screws (4).
2. Fasten the screws properly until screw head is lower than the rib
and reach the base of remote control lower case to ensure they
do not damage the PCB inside the remote control (1).
Rib
Wall
Screw (4)
Remote
control lower
case
3. The feeding-out direction for the remote control cable can be
either via top, left or right side.
4. Use nipper to cut a notch at the upper case. (Select the intended
feeding-out position)
5. Route the remote control cable (2) inside the lower case in
accordance with the intended feeding-out direction. (Refer to the
illustration at below)
6. Insert fi rmly the connector of remote control cable (2) to
connector (CON1) in the upper case circuit board. (Refer to the
illustration at below)
7. Secure the remote control upper case to the lower case with the
tabs provided.
Remote
control
Top feeding-out
position
cable (2)
Left
feeding-
out
Right
position
feeding-
out
Tabs
Lower
case
Wall
Upper
case
Upper
tab
Connector
(CON1)
Remote
control
Lower
cable (2)
case
Screw (3)
Lower tab
Outlet box (JIS C 8336)
CAUTION
Connector
(CON1)
Upper case
Upper case
Lower case
Remote control cable (2)
Wall
Upper case
Upper tab
Connector (CON1)
Lower case
Screw (4)
Lower tab
Notches
Connector
(CON1)
Upper case
Upper case
Lower case
7