Installation Manual
(MONO BLOC) AIR-TO-WATER HEATPUMP
Required tools for Installation Works
1 Philips screw driver
2 Level gauge
3 Electric drill
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully before installation of (Mono bloc) Air-to-Water Heatpump system (hereafter referred to as "Mono
bloc unit").
Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure to use the correct
rating and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the seriousness is classifi ed by the following indications.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classifi ed by the symbols:
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
Carry out test run to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in
instructions. Please remind the customer to keep the operating instructions for future reference.
If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
Do not install Mono bloc unit near handrail of veranda. When installing Mono bloc unit at veranda of high rise building, child may climb up to Mono bloc unit and
cross over the handrail and causing accident.
Do not use unspecifi ed cord, modifi ed cord, join cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances.
Poor contact, poor insulation or over current will cause electrical shock or fi re.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
Do not insert your fi ngers or other objects into the unit, high speed rotating fan may cause injury.
Do not sit or step on the unit, you may fall down accidentally.
Keep plastic bag (packaging material) away from small children, it may cause suffocation.
Do not use pipe wrench to install refrigerant pipe. It might deform the piping and cause the unit to malfunction.
Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.
This unit is a multi supply appliances. All circuits must be disconnected before accessing to the unit terminals.
Do not modify the wiring of Mono bloc unit for installation of other components (i.e. heater, etc). Overloaded wiring or wire connection points may cause electrical
shock or fi re.
Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If
electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fi re.
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building regulation codes.
Must engage an authorized dealer or specialist for installation. If installation is defective, it will cause water leakage, electrical shock or fi re.
F616831
4 Spanner
5 Knife
6 Measuring tape
WARNING
7 Megameter
8 Multimeter
9 Torque wrench
ENGLISH ................ 1
ESPAÑOL ............. 10
ITALIANO .............. 19
NEDERLANDS ..... 28
PORTUGUÊS ....... 37
ΕΛΛΗΝΙΚΑ ............. 46
ČESKY .................... 55
FRANÇAIS ........... 64
DEUTSCH ............ 73
TÜRKÇE ............... 82
SVENSKA ............. 91
NORSK ............... 100
SUOMI ................ 109
DANSK ............... 118
39.2 N•m (3.9 kgf•m)
58.8 N•m (5.8 kgf•m)
10 Gas leak detector
1
Tabla de contenido
loading

Resumen de contenidos para Panasonic WH-MXC16G9E8

  • Página 11: Bomba De Calor Aire-Agua (Mono Bloc)

    Manual de instalación BOMBA DE CALOR AIRE-AGUA (MONO BLOC) Herramientas Necesarias para Trabajos de Instalación 7 Megóhmetro 39,2 N•m (3,9 kgf•m) 1 Destornillador de Estrella 4 Llave Inglesa 58,8 N•m (5,8 kgf•m) 5 Cuchillo 2 Indicador de Nivel 8 Multímetro 6 Cinta métrica 10 Detector de fugas 3 Taladro Eléctrico...
  • Página 12: Accesorio Opcional

    Instale siguiendo cuidadosamente las instrucciones de este manual. Si la instalación es defectuosa, causará escapes de agua, descarga eléctrica o incendio. Utilice únicamente las piezas de instalación suministradas o especifi cadas. De lo contrario, la unidad Mono bloc podría vibrar, caer, así como producirse escapes de agua, descargas eléctricas o un incendio.
  • Página 13: Diagrama De Dimensiones

    Diagrama de dimensiones Componentes Principales 1283 (VISTA SIN CUBIERTA) Vista frontal Vista posterior 83,5 Vista inferior Conector de manguera de drenaje DETALLE A (SIN CUBIERTA OLP) Vista sin la tapa superior de la carcasa Nombre de componente Nombre del conectores 1 PCB Impulsión Tubo de retorno...
  • Página 14: Instalación De La Unidad Mono Bloc

    • Elija el sellador adecuado que pueda soportar las presiones y INSTALACIÓN DE LA UNIDAD temperaturas del sistema. • Asegúrese de usar dos llaves inglesas para fi jar la conexión. Apriete MONO BLOC las tuercas con la llave dinamométrica: 117,6 N•m. •...
  • Página 15 Terminal en la unidad Mono bloc (Cableado de alimentación eléctrica) Terminales del dispositivo de aislamiento de la alimentación eléctrica (Medio de desconexión) Suministro eléctrico 1 Suministro eléctrico 2 Cable de Regulación Solar (Opcional) Cable de Válvula 3 Vías Solar (Opcional) Magneto térmico con Interruptor Diferencial de la Cable de control externo (Opcional)
  • Página 16: Requisitos De Conexión Y Pelaje De Cable

    13 14 15 16 17 18 Terminales en la unidad Mono bloc 9 10 11 12 19 20 21 22 23 Cable de hilo Cable de Cable de Cable de Cable de Cable de Cable de Cable de Cable de Válvula Cable de termostato sonda...
  • Página 17: Accesorios Adjuntos

    (disponible en tiendas Cable de mando a Longitud (15 m) Pata superior distancia locales) Núm. de pieza DS3744 (Panasonic Co., Tornillo Instalación del mando Conectores Ltd.) o equivalente. (M4 montado a a distancia en una caja (CON1) 2.
  • Página 18 Antes de ajustar el caudal de agua, asegúrese de que el volumen total de agua en la instalación es de al menos 50 litros para el lado de calentamiento. El ajuste por defecto es VELOCIDAD 6 para WH-MXC16G9E8. Asegúrese PROCEDIMIENTOS DE de que el tasa de fl...
  • Página 19: Comprobar Magneto Térmico Con Interruptor Diferencial

    COMPROBACIÓN DE PRESIÓN PREVIA DEL COMPROBAR PURGADOR d VASO DE EXPANSIÓN b La purgador d se ha de instalar en todos los Enchufar puntos altos en un circuito hidráulico de sistema • (girar en Se instala un vaso de expansión b con una capacidad de 10 L de aire cerrado.
  • Página 128 Memo...

Tabla de contenido