EWMIM model
Fan coil application
Cooling capacity MIN/NOM/MAX (1)
ESEER +
Nominal cooling capacity (1) (*) EN 14511:2013
EER EN 14511:2013 (1) (*)
ESEER EN 14511:2013
Heating capacity MIN/NOM/MAX (2)
Nominal heating capacity (2) (*) EN 14511:2013
COP EN 14511:2013 (2) (*)
Application radiant
Cooling capacity MIN/NOM/MAX (3)
Nominal cooling capacity (3) (*) EN 14511:2013
EER EN 14511:2013 (3)
Heating capacity MIN/NOM/MAX (4)
Nominal heating capacity (4) (*) EN 14511:2013
COP EN 14511:2013 (4) (*)
Sound pressure (5) (∆)
Sound power (6) (∆)
Scroll compressor
Fans
Heat exchanger water content
Water buffer tank content
Heat exchanger nominal flow water side (1)
Residual head (P0/ASP0 installation) (1)
Residual head (PI0/ASPI0 installation) (1)
Residual head (P1/ASP1 installation) (1)
Amount of R410A refrigerant
Amount of Oil PVE
Electrical data
Absorbed power in summer mode NOM (1) (●)
Absorbed power in winter mode NOM (2) (●)
Absorbed power in summer mode NOM (3) (●)
Absorbed power in winter mode NOM (4) (●)
Pump absorbed power (P0/PI0-ASP0/ASPI0)
Pump absorbed power (P1/ASP1)
Electrical power supply
Auxiliary power supply
Nominal current
Maximum current (■)
Pump absorbed current (P0/PI0-ASP0/ASPI0)
Pump absorbed current (P1/ASP1)
Dimensions
Width P0/PI0/P1
Width ASP0/ASPI0/ASP1
Height P0/PI0/P1
Height ASP0/ASPI0/ASP1
Depth P0/PI0/P1
Depth ASP0/ASPI0/ASP1
Water connections
(1) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5°C.
(2) In the following conditions: evaporator
inlet air temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature
differential at evaporator 5°C.
(3) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 18°C; temperature differential at
evaporator 5°C.
(4) In the following conditions: evaporator
inlet air temperature 7°C B.S., 6°C B.U.; hot
water temperature 35°C; temperature
differential at evaporator 5°C.
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXOS / ANLAGEN / ANEXOS
(5) Sound pressure level in dB(A) referring to
a 5 m distance from the unit, in directionality
factor equal to 2.
(6) Sound power level in dB(A) on the basis
of measurements taken in accordance with
UNI EN-ISO 9614 and Eurovent 8/1
Standards.
(■) Current drawn by the compressor and
fans.
(●) Power absorbed by the compressor and
fans.
(*) The data according to EN14511 refer
staging P0/PI0/ASP0/ASPI0. Refer to the
section "Attachments Technical Note" to the
data of the establishment P1/ASP1.
92
117
kW
8,3/16/17
5,87
kW
16,2
2,98
5,15
kW
6,8/18,0/19,1 10,1/24,6/27,2
kW
17,7
3,32
kW
11/20,1/21,2 14,5/27,5/29,3 15,7/31,7/32,6
kW
20,3
3,90
kW
7,5/19,1/20,1 9,7/25,3/27,9 10,2/29,4/31,6
kW
18,8
4,10
dB(A)
46
dB(A)
72
Scroll regulated by inverter
n° x kW
2x0,3
l
1,5
l
110
l/h
2800
kPa
89/87
kPa
89/87
kPa
148/146
See serial number plate
See compressor plate
kW
5,37
kW
5,3
kW
5,14
kW
4,55
kW
0,3
kW
0,6
V-ph-Hz
V-ph-Hz
A
12
A
16,5
A
1,37
A
2,72
mm
1522
mm
1625
mm
1280
mm
1590
mm
600
mm
600
1 ½"
Ø
(∆) With accessory SIL, the value decreases
by 2dB(A).
ESEER (European Sesonal EER) European
seasonal average efficiency.
ESEER+ with AdaptiveFunction Plus logic.
124
128
12/23,5/24,8
12,8/26,7/27,8
5,37
5,26
23,8
27,0
2,84
2,97
4,75
4,70
10,7/28,8/31
24,3
28,5
3,26
3,28
27,8
32,0
3,87
3,89
25,0
29,1
4,10
4,10
48
49
74
75
2x0,3
2x0,3
1,9
1,9
110
110
4000
4600
89/84
76/69
89/84
76/69
116/111
126/119
8,39
9,10
7,5
8,7
7,19
8,20
6,12
7,1
0,3
0,3
0,6
0,82
400-3+N-50
230-1-50
15
15
23,9
23,9
1,37
1,37
2,72
1,58
1522
1522
1625
1625
1280
1280
1590
1590
600
600
600
600
1 ½"
1 ½"