Hitachi ED-X50 Manual De Usuario página 104

Tabla de contenido
Communication settings
1. Protocol
19200bps,8N1
2. Command format
Byte Number
Command
Action
<SET>Change setting to
desired value [(cL)(cH)]
by [(eL)(eH)].
<GET>Read projector
internal setup value [(bL)
(bH)] .
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
<EXECUTE> Run a
command [(bL)(bH)].
[Header code], [Packet], [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.
[CRC fl ag]
For byte number
[Action]
Set functional code to byte number 7, 8.
<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
Refer
the
command table above.
to
[Type], [Setting code]
For byte number
("h" shows hexadecimal)
0
1
2
Header
code
Packet
L
H
BEh EFh
03h
5, 6,
RS-232C Communication command table
refer to
9 〜 12
RS-232C Communication command table
, refer to
RS-232C Communication (continued)
3
4
5
Header
Data
CRC
size
fl ag
L
H
L
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
06h 00h
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
6
7
8
9
10
Data
Action
Type
H
L
H
L
H
11
12
Setting
code
L
H
.
.
9