Safety Notes; Replacement Parts - Grohe EUROECO COSMOPOLITAN E Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Safety notes

Prevent danger resulting from damaged voltage
supply cables. If damaged, the voltage supply cable
must be replaced by the manufacturer or his
customer service department or an equally qualified
person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
Fitting with battery:
• Voltage supply:
Fitting with switched-mode power supply (42 464):
• Voltage supply:
• Power consumption:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time:
(0 - 19 s adjustable)
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape:
(2 3/4" - 7 7/8" adjustable)
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa (72.5 psi), a pressure-
reducing valve must be installed.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
Undesired water
• Sensor system detection zone set too high
flow
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
1
6V lithium battery type CR-P2
100-240 V AC 50-60 Hz/6.75 V DC
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
for local conditions
English
Functions, programme selection,
see technical product information,
www.grohe.com/tpi/euroeco-ce
Installation
Flush piping system prior and after installation of
fitting thoroughly!
Open cold and hot water supply and check connections
for leakage.
Operation and settings,
see technical product information, 99.0438.xxx.
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
2.4 W
Setting mode is automatically terminated after 3 minutes.
11 s
Maintenance
1 s
•Shut off hot and cold water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
4 3/4"
necessary.

Replacement parts

IP 59K
see page 8 (* = special accessories)
,
A
Care
2
For directions on the care of this fitting, please refer
2500 V
to the accompanying Care Instructions.
100 °C
Remedy
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
5
, see page 1 - 3.
, see page 4.
Tabla de contenido