Troubleshooting - Echo EGi-4000 Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

Problem
Engine will not start.
Engine hard to start.
Engine lacks power.
AC receptacle does not work.
DC receptacle does not work.
If problem persists after trying the above solutions, contact customer service or an authorized dealer for assistance.
As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance
section. It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing
to perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause
irreversible engine damage and/or void your warranty.
Possible Cause
On/off/choke lever is STOP position.
Fuel valve is OFF.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Spark plug faulty, fouled, or improperly
gapped.
Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty fuel filter.
CO sensor LED is flashing red, indicating
a CO hazard.
CO sensor LED is flashing yellow and/
or making an audible chirp, indicating
a sensor fault.
Water in gasoline.
Weak spark at spark plug.
Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty air filter.
Item plugged in is defective.
Generator is overloaded.
Circuit breaker is tripped.
Circuit breaker is tripped.
NOTICE
English
Solution
Turn on/of/choke lever to RUN position.
Turn fuel valve to ON position.
Fill fuel tank.
Drain entire system and refill with fresh
fuel.
Engine is equipped with low oil shut-
down. If engine lubricant level is low,
it must be filled before it will start.
Check engine lubricant level and fill, if
necessary.
Replace spark plug.
Drain fuel and carburetor. Refuel with
fresh gasoline.
Contact an authorized dealer.
Leave area immediately and relocate
to an open outdoor area. Ventilate area
thoroughly before occupying again.
Ensure the generator is located in an
open outdoor area at least 20 feet (6 m)
away from all doors, windows, and oc-
cupied spaces, and point exhaust away
from occupied structures.
The CO sensor needs to be repaired
or replaced. Contact customer service
or an authorized dealer for assistance.
Drain entire system and refill with fresh
fuel.
Contact an authorized dealer.
Drain fuel and carburetor. Refuel with
fresh gasoline.
Clean or replace as needed.
Try a different item.
Remove loads and press the reset
button.
Reset the AC circuit breaker.
Reset the DC circuit breaker.
21
Tabla de contenido
loading

Tabla de contenido