Craftsman CMXECXM301 Manual De Instrucciones página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ENGLISH
WARNING: RISK FROM MOVING PARTS (Cont.)
Attempting to operate compressor
with damaged or missing parts or
attempting to repair compressor
with protective shrouds removed
can expose you to moving parts
and can result in serious injury.
WARNING: RISK OF UNSAFE OPERATION
What can happen
Unsafe op er a tion of your air
compressor could lead to se ri ous
in ju ry or death to you or others.
WARNING: RISK OF FALLING
What can happen
A portable compressor can fall
from a table, workbench, or roof
causing damage to the compressor
and could result in serious injury or
death to the operator.
Specifications
Model
Bore
Stroke
Voltage/Hz-Single Phase
Minimum Branch Circuit Requirement
Fuse Type
Air Tank Capacity
Any repairs required on this
product should be performed
by authorized service
center personnel.
How to prevent it
Review and understand all
instructions and warnings in
this manual.
Be come fa mil iar with the op eration
and con trols of the air compressor.
Keep operating area clear of all
persons, pets, and obstacles.
Keep chil dren away from the air
compressor at all times.
Do not operate the product when
fatigued or under the influence
of alcohol or drugs. Stay alert at
all times.
Never defeat the safety fea tures of
this prod uct.
Equip area of operation with a
fire extinguisher.
Do not op er ate machine
with missing, broken, or
un authorized parts.
Never stand on the compressor.
How to prevent it
Always operate compressor in a
stable secure position to prevent
accidental movement of the unit.
Never operate compressor on a
roof or other elevated position.
Use additional air hose to reach
high locations.
CMXECXM301
2.68" (68.014 mm)
1.50" (35 mm)
120/60
15 amps
Time Delay
30 Gallons (113.5 liters)
Specifications (cont.)
Model
Approximate Cut-in Pressure
Approximate Cut-out Pressure
SCFM @ 40 psig
SCFM @ 90 psig
Tank Fill Time
Duty Cycle
Weight
Regulated Pressure Rating (Approximate)
Quick Connect Type
*Tested per ISO 1217
Refer to Glossary for abbreviations.
GLOSSARY
CFM:
SCFM: Standard cubic feet per minute; a unit of measure of
air delivery.
PSIG: Pounds per square inch gauge; a unit of measure
of pressure.
PSI: Pounds per square inch; a unit of pressure.
Code Certification: Products that bear one or more of the
following marks: UL®, CUL, CULUS, ETL®, CETL, CETLUS, have
been evaluated by OSHA certified independent safety
Cut-In Pressure: While the motor is off, air tank pressure
drops as you continue to use your accessory. When the tank
pressure drops to a certain lower level the motor will restart
automatically. The low pressure at which the motor
Cut-Out Pressure: When an air compressor is turned on
and begins to run, air pressure in the air tank begins to build.
It builds to a certain high pressure before the motor
automatically shuts off, protecting your air tank from
pressure higher than its capacity. The high pressure at which
Branch Circuit: Circuit carrying electricity from electrical
Duty Cycle: For proper operation of your air compressor, it
is recommended that a 50% duty cycle be maintained; that
is, the air compressor should not run more than 30 minutes in
any 60 minute period.
Well-ventilated: A means of providing fresh air in exchange
for dangerous exhaust or vapors.
Dedicated circuit: An electrical circuit reserved for the
exclusive use of the air compressor.
ASME: American Society of Mechanical Engineers. Indicates
that the components are manufactured, tested and
inspected to the specifications set by ASME.
4
CMXECXM301
135 psi
175 psi
7.7 *
6.2 *
6.5 minutes
50%, ex. 30 minutes each hour
Approximately 152 lbs (69 kg)
3-150 psi
1/4" (6.4mm) Universal
Tabla de contenido