Sony SRX-R110 Manual De Instalación página 28

Ocultar thumbs Ver también para SRX-R110:
Idiomas disponibles

Idiomas disponibles

G." However, the adjustment of "Gain G" may affect
the contrast of the picture.
10
Enter the adjusted white point values in the x and y text
boxes for "W" under "Projector Color Gamut."
11
Select "Red-1," "Green-1" or "Blue-1" from the Test
Pattern drop-down list to display each test pattern.
Use the Chroma Meter to measure the x and y values
for each color.
12
Enter the measured values in the x and y text boxes for
"R," "G" and "B" under "Projector Color Gamut."
13
Click the CALC button.
The color characteristics of the projector are corrected.
14
Click the APPLY button.
The corrected values are stored in the projector.
15
Repeat step 5 to readjust the luminance of the
projector.
Correction of the color characteristics may result in a
change of the luminance.
16
Select "Off" from the Test Pattern drop-down list to
turn off the test pattern on the screen.
Note
The corrected values and the target values may not be
identical due to some elements such as the accuracy of the
Chroma Meter.
Be sure to set "Contrast" to 90 and "Brightness" to 50 in
"Signal Adjust" (page 22) of the PICTURE CONTROL
window so that the corrected color characteristics can
affect the displayed picture.