4. S
ervIce
4.1 P

reVentiVe mAintenAnce

Without a tool clamped in check no-load speed
periodically and after each maintenance. Even if
the machine still operates perfectly, the motor
should be removed, cleaned and the four slides checked
for wear by a specialist after approx. 300 to 400 operating
hours.
4.1.1 r
ePlAcement of the exhAust Air hose
Detach the exhaust air hose from the swivel ring, and re-
place it.
4.1.2 r
ePlAcement of the suPPly hose
Remove the exhaust air hose (see 4.1.1).
Detach the hose clamp, and pull the supply hose off the
connection nipple.