Connecting Electrical Loads

1. Let engine stabilize and warm up for a few minutes
after starting.
2. Ensure circuit breaker on control panel is in "On"
position.
3. Plug in and turn on the desired 120 and/or 240 Volt
AC, single phase, 60 Hz electrical loads.
NOTICE When plugging into the 120 Volt receptacles, plug
items to be powered in sequence as shown below.
1
2
NOTICE
• DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacles.
• DO NOT connect 3-phase loads to the generator.
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOAD THE GENERATOR. See Don't
Overload Generator.
NOTICE Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices connected
to it.
• DO NOT exceed the generator's wattage/amperage capacity. See
Don't Overload Generator in the Operation section.
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• Turn electrical loads OFF and disconnect from generator before
stopping generator.

Stopping the Engine

1. Turn OFF and unplug all electrical loads from generator
2. Let engine run at no-load for several minutes to
3. Push engine rocker switch to OFF or O position.
• DO NOT stop engine by moving choke control to "Choke"
position
3
4. Move fuel valve to "Off" position.

Warm Weather Operation

This generator engine is equipped with WeatherGuard, an
4
innovative feature to prevent carburetor icing in cold weather
conditions. WeatherGuard has been engineered to operate in
all weather conditions. However, product performance can be
increased when operating the generator solely in warm
weather by removing the WeatherGuard shield (A).
Remove the two nuts (B) and loosen the fastener (C) as
shown. Store shield and fasteners for future cold weather
operation.
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
stabilize internal temperatures of engine and generator.
WARNING Fuel and its vapors are extremely flammable
and explosive which could cause burns,
fire or explosion resulting in death,
serious injury and/or property damage.
(
)
.
B
A
C
13