Fein AFSC18Q Manual De Instrucciones página 14

Ocultar thumbs Ver también para AFSC18Q:
Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000357-001.book Page 14 Monday, January 28, 2019 11:44 AM
en
14
Assembly instructions.
Before mounting or replacing application tools or accessories, remove the bat-
WARNING
tery. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
For all work or when changing application tools, always wear protective gloves.
CAUTION
Danger of injury from the sharp edges of the application tools. Application
tools can become very hot while working. Danger of burns!
Changing the tool.
Do not switch the power tool
CAUTION
on while the clamping lever is
open. Otherwise there is danger of crushes or
contusions to the hand and fingers.
Do not actuate the clamping
CAUTION
lever while the power tool is
running. Otherwise there is danger of injury.
Do not reach into the area of
CAUTION
the clamping jaws. Otherwise
there is danger of crushes or contusions to
the fingers.
Inserting the application tool (figure 4).
Clean the tool holder and the application tool.
In the starting position, the clamping jaws in
the tool holder are together. In this position,
the application tool can be clipped-in easily.
Do not operate the power tool
CAUTION
with open clamping jaws and
without an application tool! This could dam-
age the power tool.
When the clamping jaws are
CAUTION
open before the application
tool is inserted, pivot the clamping lever
toward the front and then back again. The
clamping jaws are closed now. The application
tool can be inserted.
Fig. 4
1.
2.
3.
loading

Este manual también es adecuado para:

Afsc18qsl7 129 27 65 09 0