EINHELL MKA 2800 E Manual De Instrucciones página 17

Equipo de aire acondicionado portátil
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Anleitung_MKA_2800_E_SPK7:_
Whenever the device has been transported
(inclined positions), leave for at least one hour
before connecting to a socket outlet.
In the cooling function the warm exhaust air must
be transferred outside by the exhaust air hose.
An opening in the wall or window must therefore
be provided.
Please note that the minimum distance between
the equipment and the wall to the side and rear
must be 50 cm. The minimum distance to other
objects at the front must be 2 m.
5.1. Replacing the carbon filter (Fig. 4)
1. Take out the filter frame
2. Remove the filter fastener from the filter frame
3. Take the carbon filter out of the bag
4. Place the carbon filter in the filter frame
5. Fasten the filter with the filter fastener
6. Slide in the filter frame
5.2. Installing the exhaust air hose (Fig. 5)
Use only the supplied exhaust air hose (Ø 120 mm).
The length of the exhaust air hose can be varied
from between 300 mm to 1500 mm. For the most
effective cooling the hose should be as short as
possible. Avoid kinks are excessive bends in the
hose so that the exhaust air can be transferred out
without hindrance. If you ignore this advice, the
device as a whole may overheat and shut down. This
could result in damage to the device.
Warning!
The length of the exhaust air hose is matched to the
technical specifications of the device. Never extend
the hose as this could lead to malfunctions or faults
on the device.
Under certain circumstances a partial vacuum may
develop in the room, which will lead to a reduction in
the cooling performance of the device. To prevent
this from happening you must ensure that there is a
supply of air to the room (leave the door to the room
slightly open).
Fitting the exhaust air hose through an open
window (Fig. 6)
Secure the exhaust air hose to the exhaust air
connection port (12) by turning it anti-clockwise.
Secure the exhaust air hose to the wall adapter
(13) by turning it anti-clockwise.
Push the exhaust air connection port into the
guide in the connection opening for the exhaust
air hose.
Secure the exhaust air hose to the feed-through
ring by turning it anti-clockwise. Use the foam
parts and shorten them if required. Insert the
18.09.2007
15:00 Uhr
Seite 17
feed-through ring into the foam opening. The
warm air will be removed to the outdoors. Secure
the window so that the foam is kept firmly in
place.
Note: Take appropriate precautions to prevent
unauthorized entry through the window.
Installing the exhaust air hose through the
window or wall (Fig. 7)
Cut or chisel a hole with a diameter of approx.
130 mm in the window or wall.
Secure the exhaust air hose (14) to the exhaust
air connection port (12) by turning it anti-
clockwise.
Guide the exhaust air hose (14) through the
window or wall and secure it on the outside to
the connection port (12) by turning it anti-
clockwise.
Screw the connection port (12) to the external
wall.
Place the cover cap (17) on the outside of the
connection port (12) when the unit is not being
used.
6. Operation
6.1 Description of the control elements (Fig. 8)
1. "ON/OFF" switch – ON/OFF
2. LED "Compressor on"
3. "SPEED" switch – fan speed
4. LED "Fan: Slow"
5. LED "Fan: Fast"
6. "MODE" switch
7. LED "Automatic mode set"
8. LED "Cool mode set"
9. LED "Fan function set"
10. "TIMER" switch
11. LED "Timer on"
12. "Down" switch – temperature lower
13. "UP" switch – temperature higher
14. Remote control sensor
15. LED indicator panel
16. LED "Room temperature display"
17. LED "Nominal temperature display"
6.2 Switching the device on and off
Press the On/Off switch. The device starts up
automatically. If the ambient temperature:
is higher than 23°C the device will run in cooling
mode;
if it is between 20°C and 23°C the device will run
in fan mode.
The status of the device, or mode in which it is
running, will be shown by the corresponding LEDs
(see indicator panel).
GB
17

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

23.603.15

Tabla de contenido