Firman H08051 Manual Del Usuario página 23

Ocultar thumbs Ver también para H08051:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Connect the regulator to both LPG cylinder and
generator.
NOTE: Do not place the LPG cylinder in the path of muffler outlet.
4. Fully open the LPG cylinder knob.
5. Turn the fuel selector switch to "LPG" position.
NOTE: When the fuel selector switch is turned
to the "LPG" position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
6. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
English
7. Move choke lever located on engine to "START"
position.
8. PULL TO-PRIME:
-
Pull the starter cord 1-2 times. Pull slowly until
resistance if felt and then pull rapidly.
1-2 Times
9.Move the choke lever to the "RUN" position.
10. PULL TO RUN:
-
-
Pull the starter cord slowly until resistance if felt
and pull rapidly to run the unit.
If the engine fails to start in 1-2 pulls with choke in the
"RUN" position, then move choke lever to "START"
position and repeat the "PULL-TO-PRIME" step.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
REMINDER: MUST HAVE SOLID RED INDICATOR
LIGHT TO BE ABLE TO START THE GENERATOR.
THE GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
Page 21
Customer Service: 1-844-FIRMAN1
Tabla de contenido

Solución de problemas

loading

Tabla de contenido