7. CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
7.1 Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
8. TECHNICAL SPECIFICATIONS
Power supply:
Max. power output:
Max. current:
Number of control-channels:
Max. output/channel:
Max. current/channel:
Integrated programs:
Output sockets:
Fuse:
Dimensions (WxDxH):
Minimum mounting depth:
Weight:
Please note: Every information is subject to change without prior notice. 04.01.2006 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz ~
3680 W
16 A
4
1150 W
5 A
16
4 IEC sockets
4 x F 6.3 A, 250 V
482 x 163 x 44 mm
19" mounting dimensions with 1 u
230 mm
3 kg
16/28
70064223_V_1_0.DOC