Operation; Cleaning And Maintenance; Technical Specifications - EuroLite MIK Outdoor Spot Series Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After you connected the effect to the mains, the MIK Outdoor Spot starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Version: 70W
Power supply:
Power consumption:
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
E-27 / 40000020-28
230 V AC, 50 Hz ~
85 W
17/33
R7s / 40000030-38
230 V AC, 50 Hz ~
85 W
00019783.DOC, Version 1.3
Tabla de contenido
loading

Tabla de contenido