Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need two 230 V/15 W E-14 lamps.
Procedure:
Step 1: Unscrew the fixation-screws of the housing-ball.
Step 2: Remove the front housing-cover.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Put the new 230 V/15 W E-14 lamp into the lamp-socket.
Step 5: Replace the housing-cover and tighten the screws.
OPERATION
Install the device on a plane surface.
Connect the fixture to the mains with the power-plug.
With the POWER-switch, you can switch the device on and off.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lenses have to be replaced when they are obviously damaged,
so that their function is impaired, e. g. due to cracks or deep scratches!
Do not operate this device with opened housing-balls!
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!