Seiko I Infotech Inc SII IP-7700 Guia De Inicio Rapido página 62

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 172
8
Clean the head guard at the both sides of the
carriage using the cleaning stick.
Carriage
9
Move the carriage manually onto the platen
(left side) and secure the spittoon unit with the
knob screw.
10
Close the cap cover and then close the front
cover.
The carriage returns automatically to the home
position.
Note
-
Do not leave the carriage away from the capping unit.
Finish the procedure above within five minutes and cap the
print head. Or the print head dries, which may result in a
malfunction.
Head guard
(gray parts)
Spittoon unit
Knob screw
<Cleaning the madia edge guard>
Note
-
Perform the procedure below withe gloves on.
1
Open the front cover.
2
Dip a cleaning swab in the cap cleaning liquid.
Checking visually, scrub stains on the media
edge guard.
3
Clean the stains with a soft and clean cloth.
4
Close the front cover.
<Performing normal cleaning>
Select PH.REC MENU from the operation panel, and select
NORMAL ALL for cleaning.
<Performing nozzle print>
Select ADJUST MENU from the operation panel, and select
TEST PRINTS to perform the nozzle print.
Check for nozzle-out and incorrect print. The nozzle print
is also used to check the print head before the first print
everyday or after the head is moved out of the capping unit
for cap cleaning. If nozzle-out is found in the nozzle print,
perform the normal cleaning.
Note
-
Do not leave the print head outside the capping unit. Finish
the nozzle print within five minutes and cap the print head.
After the nozzle print is completed, perform normal cleaning
for the print head.
61
Tabla de contenido
loading

Tabla de contenido