ART. 640
O
- ø 40 mm drain outlet connection
(for fixed installation only - optional)
- Cable outlet for connection to a.c. supply
PLUMBING CONNECTIONS
EMPTYING
The Teuco minipool has a drain valve.
The tub can be emptied simply by connecting a hose to the valve,
or alternatively, by making a permanent connection to the main
drain (O). In this instance it will be advisable to install a trap with
valve, which will serve as the foot valve.
IMPORTANT: before making any permanent connection to the
main drain, contact the local authorities to check on
regulations governing the disposal of chemically treated water.
FILLING
The recommended method of filling the Teuco minipool is to use
hose, taking care not to immerse the end as this could allow
reflux of water back into the main.
MPORTANT: if the intention is to connect the minipool
permanently to the water supply, suitable non-return devices
must be incorporated to prevent reflux back to the water main.
Contact the local authorities before proceeding with this type
of installation.
HEAT EXCHANGER CONNECTIONS
HEAT EXCHANGER SPECIFICATIONS
Minimum output of boiler
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum flow of recirculation pump (P)
Minimum head of recirculation pump (P)
Water temperature in boiler
Boiler pipe connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The minipool is provided with a switch box (M) containing a relay with a "normally open voltage-free" contact (3A Max - spare terminals connected to Black and
White conductors) that can be used as on/off switch control for a boiler, a recirculation pump, a zone valve or other appliance/component. Install the pipes (C e
C1) carrying water to and from the boiler as indicated.
PRE-INSTALLATION Art. 640
7 kW
1600 l/h
. . . . . . . . . . . . . . . .
1,8 m.
. . . . . . . . . . . . . . . . . . .
80 °C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3/4"
ELECTRICAL CONNECTIONS
The electrical power supply must be in compliance with statutory
regulations for the country of installation.
The product must be connected to the mains power via an
omnipolar switch (I) with an opening between contacts that
guarantees complete disconnection in excess voltage category III
conditions (minimum 3 mm), installed outside areas 0,1,2,3 (IEC
60364-7-701).
Make certain the appliance is connected to the power source by
way of a residual current device with minimum threshold ≤30mA.
The connection must include a connection to the earth system
and must be:
- permanent
- able to handle the rated current (see data plate)
- specified to liquids ingress protection category IPX5
ZONA 2
1,5 m
2 m
CALDAIA
BOILER
1090
O =
1090
ZONA 1
2 m
ZONA 0
ZONA 0
3/4"
3/4"
EN
ZONA 2
1,5 m
17