Outputs; Interfaces; Mechanical Data - Kübler CODIX 550 Manual Del Usuario

Ocultar thumbs Ver también para CODIX 550:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Digital inputs
Input MPI*
1. Function Display-Hold
*MPI: Multi Purpose Input
Switching level
Input MPI and Input KEY are galvanically isolated

2.2.3 Outputs

Auxiliary power supply output for measuring transducer/sensor
AC models
DC models
The auxiliary power supply is galvanically isolated from the inputs, outputs and
the interface.
2.2.4 Interface
Available options
Baud rate
Address
Data format
Character format
The interface is galvanically isolated from the inputs, outputs and auxiliary voltage.

2.3 Mechanical Data

Housing
Dimensions (W x H x D)
Panel cut-out (B x H)
Mounting depth
Weight
Protection
Connections
Power supply and output:
Measurement and control input:

Interfaces:

Cleaning:
6
Function of the inputs depending on set up
to stop the instantaneous value
logical 0
logical 1
Min. pulse duration
voltage output 10 V DC ±2%, 30 mA
and
voltage output 24 V DC ±15%, 50 mA
only voltage output 10 V DC ±2%, 30 mA
RS232, RS485, RS422
600, 1200, 2400, 4800, 9600, 19200 programmable
00 ... 99 programmable
8 Data bit, no parity, 1 stop bit
advanced ASCII character format of
IBM-PC without graphic characters
Housing for control panel 96 x 48 mm according to
DIN 43 700, RAL 7021
96 x 48 x 90 mm
92+0,8 x 45+0,6 mm
approx. 83 mm
approx. 220 g
IP 65 (on the front side)
1 x screw terminal, 8-pole, RM 5.08
1 x screw terminal, 11-pole, RM 3.81
(*) 1 x screw terminal, 5-pole, RM 3.81
The front of the unit is only to be cleaned
with a soft wet (water !) cloth.
0 ... 2 V DC
4 ... 30 V DC
> 5 ms
www.kuebler.com
Tabla de contenido
loading

Tabla de contenido