9.
Select the green tubing attached to the auxiliary tap and fi rmly insert the
free end into the Input Connector (9.5mm) of the fi lter bracket (Fig. 4).
10. Select the blue tubing attached to the auxiliary tap and fi rmly insert the
free end into the Output Connector (8mm) of the fi lter bracket (Fig. 4).
NOTE: The fi tting grips before it seals. Ensure the tubing is fully pushed in until
the mark disappears as a check on each of the tubing connections in steps
9,10.
fi g. 4
INSTALLER NOTE: The hose nipple contains a fl ow controller which is critical to
tap performance and must be included in the installation of this tap kit.
11. To connect to cold water supply, the following parts will be necessary:
Tee with connection to isolation valve
Isolation valve with DN15 / 1/2" NPT thread (Male)
These are essential parts that are customer supplied – not included with
the system.
12. To complete installation unscrew the plastic shipping plug from the hose
nipple and discard (Fig. 5).
13. Attach the hose nipple to the isolation valve with DN15 1/2" male NPT
already installed using plumber's tape (Fig. 6).
14. Remove nut from hose nipple and slide onto the red hose (Fig. 7).
2
All manuals and user guides at all-guides.com
fi g. 5
fi g. 6
fi g. 7
15. Push red hose over barb on hose nipple (Fig. 8) and tighten nut with a
wrench.
16. Plug the DC jack of the power adapter into the back of the electronic
module.
17. Replace the electronics module on the fi lter bracket.
18. Replace the top shroud on the System (Fig. 9).
19. Turn the handle on the auxiliary tap counterclockwise to its continuous
fl ow position.
fi g. 9
Checking for Leaks
1.
Open the water supply isolation valve and turn on the auxiliary tap. It will
take a short time for the water to saturate the fi lter and then emerge
from the auxiliary tap. When treated water begins to fl ow from the
auxiliary tap, continue to let it run for a constant 5 minutes to eliminate
air pockets and to clear the System of any carbon dust. (It is normal for
a small amount of carbon dust from the fi lter manufacturing process to
be seen during the initial constant fl ow.) If the water does not clear of
carbon dust within 15 minutes constant fl ow, call Business Services.
2.
Plug the power adapter into a suitable electrical outlet.
NOTE: The blue lights will blink sequentially on the display when water is fl owing
through the system. If it is not blinking, see Troubleshooting in the owner's
manual, pages 10–11.
3.
Turn off the auxiliary tap and check for any signs of leakage (bubbling or
water drips around fi ttings). If leaking occurs, close the water supply
isolation valve. Make sure the tubing are inserted completely. Open
isolation valve and check the System to verify that there are no leaks.
4.
Your eSpring™ Water Treatment System is now ready to serve you
whenever you want great-tasting, healthier water.
5.
After you have connected your tap to the system and water, check your
electronic module display to be sure your water treatment system is
functioning properly.
fi g. 8