3 GETTING STARTED (continued)
3.3 SELECTING THE UNITS
The gauge can display readings in MPa (Megapascals) or PSI
(Pounds per Square Inch).
1
Press
MENU
2
Press
MENU
3
Press
3.4 RESETTING THE GAUGE
The gauge has a gauge reset function which restores the original
factory settings.
1
Press
MENU
2
Press
switch off.
3
To cancel the reset request, press
'CANCL' followed by

4 SECURING THE DOLLY

1
Identify the dolly test surface.
2
Ensure test surface of dolly is clear of
old adhesive - see Section 8.2
'Cleaning the Dolly' on page 7.
3
Wipe dolly test surface and sample
area with a solvent to remove oil and
grease.
4
Apply a thin, even coat of adhesive to
dolly test surface. If adhesive is low
viscosity, see Section 9 'Using a Dolly
Plug' on page 8.
5
Press dolly on to sample for about 10 seconds.
6
Leave dolly undisturbed for at least 15 minutes (preferably for 2
hours or more), to allow the adhesive to harden.
7
If required, score the coating around the dolly using a dolly cutter
- see Section 10 'Spares & Accessories' on page 9.
www.elcometer.com
until UNITS is displayed followed by
or
to toggle between MPA and PSI.
MAX
to select the units required.
until RESET is displayed followed by
again to confirm the reset. The gauge will reset and
to confirm.
or
MAX
to toggle to
MENU
ü
ü
R
to select.
to select.
û
ü
4