supply system with neutral conductor connected to the
earth.
The charge station must be protected by a type A residual
current device.
The power line must be protected by an adequate circuit
breaker with C curve.
The connections compartment should only be opened by
qualified staff.
Use the device exclusively for applications compliant with
its intended use.
Do not use private generators as a charging power source.
The charging station should be installed in a location that
meets the following requirements:
Protected from direct sunlight.
Sufficiently ventilated.
Far from sources of heat.
Ambient temperature between -20°C and +50°C.
Altitude above sea level up to 2000m.
Protected from rainwater, running water and other liquids.
Easily accessible.
Maintain a distance of at least 500 mm from other devices
or objects.
Do not install the charging station in:
Locations with constant dust production (both conductive
and non-conductive).
Locations with presence of corrosive vapours, acids or salts.
Locations with flammable substances.
Locations at risk of explosion.

4.1 Wall mounting

Carefully unpack the charging station, checking all parts are
intact. Keep the original packaging if it may be sent for any
repairs. The content of the package is outlined in Fig. C.
The device must be assembled in the vertical position at a
height of approximately 150cm (from the lower edge to the
floor). The assembly wall must be flat and stable.
Fasten shelf A (Fig. D-1) to the charging station with the 4
M6x12 screws supplied.
Fasten shelf B (Fig. D-1) to the wall with the 4 screws and 4
plugs supplied.
Position the device over the shelf and slide it top to bottom
parallel to the wall until all the fittings are hooked to the
respective slots (Fig. D-2). Check correct positioning, checking
it is parallel to the wall. Try to distance it from the wall to check
its correct hooking to the shelves.
Fasten the device with the specific M5x12 screws on the upper
and lower side (Fig. D-3).
Lastly, fasten the cable winder to the wall using the 2 screws
and 2 plugs supplied (Fig. D-4).

4.2 Electrical connection

The electrical connection should be installed:
In compliance with national legislation.
Only by qualified operators.
After fastening the device to the wall.
The charging station must have a dedicated power line,
protected by an adequate circuit breaker switch with C curve
and a type A residual current device (See 7.1).
For electrical connection installation:
Disconnect the power line via the circuit breaker switch
and residual current device.
Open the connections compartment on the back of the
device (Fig. E-1).
Remove the sheath from the cable and strip the cores of
the conductors (Fig. E-2).
Insert the cable using the cable gland on the lower side
(Fig. E-3).
Fasten the 3 conductors to the terminal board, respecting
L, N, PE (Fig. E-4).
Close the connections compartment.
Reposition the charging station on the wall, as previously
described.