Important! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in posi-
tion on the basin.
3.
Slide the fixation piece including the washer over the
threaded pins and tighten the nuts.
4.
Connect the supply pipes to the isolation valves; cold
right - hot left.
5.
31730000/31731000/31920000
Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter).
Rate of flow with EcoSmart:
Rate of flow without EcoSmart:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
If the continuous water heater causes any problems or there
is not enough flow of water, the EcoSmart® (5a) located
behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers, please
see page 38.
All manuals and user guides at all-guides.com
7 l/min 0,3 MPa
14 l/min 0,3 MPa
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65° C
English
No adjustment is necessary when using a continuous flow
water heater.
Spare parts (voir pages 2)
1
handle
1.1
screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator
6
pull rod
7
fixing set
8
connection hose 3/8"
9
connection hose Ø 10
10
chain for plug
11
seal
12
ball joint
Special accessories
X
special tool set
Y
seal Ø 45 mm
(order as an extra)
98532000
96338000
97406000
97209000
92730000
13912000
96657000
96016000
97206000
96321000
97109000
95008000
92036000
58085000
98996000