6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter blue
marked copper pipe.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Highest possible water pressure at
user's site in Mpa
0,1 – 0,15
0,2 – 0,3
0,4 – 0,7
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 5 l/min
Table for the throttle hose lengths to be used
8, 10 and 15 liters
without throttle hose
Throttle hose shortened to 90 mm
Cause
– Spray former calcified, dirty
–Cartridge defective, calcified
– Cartridge defective
Assembly see page 10
Symbol description
Do not use silicone containing acetic acid!
Cleaning
see enclosed brochure.
Dimensions (see page 11)
Operation (see page 12)
When the storage tank is being heated, the
spout will drip.
Spare parts (see page 13)
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Test certificate (see page 11)
Device content
Throttle hose shortened to 90 mm
Throttle hose unchanged
Adjust flow volume at corner valve
Remedy
–Clean spray former, exchanging if
necessary
– Exchange cartridge
– Exchange cartridge
up to 5 liters
Throttle hose unchanged