Optional Operation

1. Two Thermistor System
(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.
• Position 1: The room themperature is controlled by the thermistor of the wired remote-
controller, control the temperature according to the position of wired remote-
controller.
• Position 2: The room temperature is controlled by the thermistor of the main body.
• Position 3: The room temperature is controlled by lower temperature between the
temperature of main body and of remote-controller sensor.
(3) Move the slide switch to set position.
Slide switch for 2 Thermistor
(4) Close the rear cover and check if it works normally.
CAUTIO
N:
• Select the position after counselling with a customer.
• In case of cooling mode, room temperature is controlled by the main body sensor.
• To control the room temperature by a wired remote controller, install controller(room
temp. sensor) to sense the temperature more accurately.
• Manufactured in the position 3.