** BEFORE USE CHECK FOR LEAKS **
Never check for leaks with a naked eye. Always use a soapy water solution.
NOTE: Before starting the stove, check for leaks. To prevent a fire or an explosion hazard when testing
for a leak, ensure the regulator valve is securely fastened to the burner and the LP cylinder.
Always perform the "Leak Test" as described below before lighting the outdoor stove or each time the
LP cylinder is connected for use.
DO NOT smoke or allow other sources of ignition in the area while conducting a leak test.
Conduct leak test outdoors in a well-ventilated area.
DO NOT use matches, lighters, or a flame to check for leaks.
DO NOT use outdoor stove until any and all leaks are corrected. If leak persists, disconnect
propane supply and call Customer Service at 1-912-638-4724, or contact your local gas appliance
service/supplier.
Leak Test
1. In a spray bottle mix 1-2 Tbsp (15-30mL) solution, 1 part dish washing soap, 3 parts water.
2. Ensure control valves/burner knobs are in the OFF position and the regulator is securely connected.
3. Open LP cylinder valve completely by turning wheel counterclockwise.
4. Apply the solution to the hose, gas valve, regulator, and LP cylinder.
5. If bubbles form and grow on any of the tested components, there is a leak in the component.
No bubbles mean no leaks.
6. If a leak has been identified, please re-secure/tighten all components and retest starting
with steps 2-5. If leak persists, disconnect LP cylinder and call Char-Griller
at 1-912-638-4724, or contact your local gas appliance service/supplier.