Safety; Safety Instructions; Product Description; Installation - COMEM e170SC Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Safety

Safety instructions

Make sure that any person installing and operating the the
pressure relief device:
• Is technically qualified and competent.
• Fully comply with these assembling instructions.
Improper operations or misuse could cause danger to:
• life and limb
• the equipment and other assets of the operator
• the equipment proper function
Safety instructions in this manual are shown in three diffe-
rent forms to emphasize important information.
WARNING
This information indicates particular danger to life and health.
Disregarding such a warning can lead to serious or fatal injury.
CAUTION
This information indicates particular danger to equipment and/
or other property of the user. Serious or fatal injury cannot be
excluded.
This notes give important or specific information concerning the
equipment.
Safety notes on the equipment operation
Electrical installation is subject to the relevant national
safety rules.
It is mandatory to connect the grounding cable because of
safety reason.
CAUTION
Installation, electrical connection and fitting the device have to
be carried out by qualified personnel and only in accordance to
this instruction manual.
It is responsibility of the user to make sure that the device is
used for specified application only.
For safety matters, please avoid any unauthorized and
improperly works.
WARNING
All relevant fire protection regulation must be strictly observed.
4
NOTE
ELECTRONIC PRESSURE RELIEF DEVICES e170SC

Product description

The pressure relief device protects the transformer
against non-permissible increases in pressure.
Once a specific predetermined value of pressure has
been reached, the pressure relief device will open, reduce
the pressure, and reseal itself tightly after achieving the
required reduction in pressure.
WARNING
It is important to observe the limit values indicated on the
nameplate and in the manual before commissioning the device.

Installation

CAUTION
The operating and the installation requirements described in
this manual must be strictly following. If not, the device can be
damaged or a malfunction can occur.
CAUTION
The contact surface must be well leveled with a good degree of
roughness (Ra=3.2).
Remove all welding burrs to ensure that the welding seams of
the studs do not interfere with the housing flange holes (flange
slits).
During assembly it is advisable to apply a few drops of
cyanoacrylate glue on the gasket, this securing correct seat and
preventing its damaging during fastening.
Apply tightening torque on all the nuts following a cross
sequence.
The pressure relief device can be installed horizontally or
vertically. Please be sure to leave sufficient space above
the valve (min. 70mm / 2.75mm) so that the optical signa-
ler can be completely pressed out of the housing when the
1
2
device is tripping.
A
B
C
D
E
Figure 1
F
1
2
3
4
5
M16
170
235
CREATED BY
Diego Boro
APPROVED ON
-
COMPANY
COMEM
RESPONSIBLE DEPARTMENT
ITABB-9AAE306693
3
4
5
6
7
REVIEWED BY
-
DOCUMENT KIND
Component Drawing
TITLE / SUPPLEMENTARY TITLE
COMEM LPT PER CATALOGO
-
DOCUMENT ID
NV-402
© COPYRIGHT ALL RIGHTS RESE
6
7
Tabla de contenido
loading

Tabla de contenido