Package contents for concealed installation (Fig� 3�1)
Package contents for surface-mounted installation (Fig� 3�2)
Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed installation
C Designer trim, round or square
D Sensor module
Product dimensions
Ceiling / wall mounting, surface-mounted and concealed wiring (Fig� 3�4)
4� Electrical installation
An optional corner wall mount is available for mounting the HF 3360 PF.
(Prod. No. 035174 white)
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
S1 / S2 = floating relay input and output
Note on manual override function (Fig� 4�1):
A power switch for switching ON and OFF can be installed in the mains supply lead.
This is a prerequisite for the manual override function. (➔ "6� Function / operation")
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP54) double seal cable gland.
For mounting on the wall, a condensation water drainage hole (Ø 5 mm drill bit) is
marked next to the rubber seal. This must be opened if necessary.
Connection examples (Fig� 4�2)
a Control input users
b Users powered from L�
L and S1 must be connected inside the sensor�
a) Load, lighting max. 2000 W (refer to Technical specifications)
b) Sensor connection terminals
c) Indoor switch
22