Wolf ICBCT15I/S Instrucciones De Instalación Y Funcionamiento página 12

Ocultar thumbs Ver también para ICBCT15I/S:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

W O L F
U N F R A M E D
The illustrations below provide installation
specifications for Model ICBCT30IU.
For ease of installation, 838 mm cabinets are
recommended for installation of Model ICBCT30IU.
A Wolf 762 mm built-in single oven may be
installed below Model ICBCT30IU. For this
installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven. Refer to instal-
lation instructions provided with the built-in
oven for additional specifications.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 3 0 I U
762 mm
OVERALL WIDTH
104 mm
TERMINAL BOX
Overall Dimensions
M O D E L I C B C T 3 0 I U
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance*
Cut-Out Width
Cut-Out Depth
*Minimum 165 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
12
All manuals and user guides at all-guides.com
I N D U C T I O N C O O K TO P S
M O D E L I C B C T 3 0 I U
533 mm
OVERALL
DEPTH
330 mm
max
SEE COUNTERTOP
127 mm
CUT-OUT BELOW
102 mm
610 mm
762 mm
102 mm
533 mm
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
578 mm
Countertop Cut-Out
127 mm
RECESSED AREA FOR
721 mm
FLUSH MOUNT INSTALLATION ONLY
492 mm
COUNTERTOP
PROFILE
22
mm
max
8 mm
**Minimum dimension, but may be exceeded by up to 3 mm.
If Model ICBCT30IU is installed above cabinets,
electrical placement is not critical. The appli-
ance shall be installed in such a way to allow
disconnection of the appliance from the supply
mains after installation.
For Model ICBCT30IU installation options, refer
to Unframed Installations on pages 14–15.
IMPORTANT NOTE: For flush mount applica-
tions, it is recommended to measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.
457
51 mm*
mm
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
min
914 mm
min
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
33 mm
RADIUS
537 mm**
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
40 mm
838 mm
RECOMMENDED
CABINET WIDTH
762 mm
min
min
SEE COUNTERTOP
CUT-OUT BELOW
114 mm
89 mm
E
102 mm
254
min
mm
TO OVEN
OPENING
762 mm OVEN OPENING
765 mm**
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
721 mm
COOKTOP
CUT-OUT WIDTH
11 mm
RADIUS
CUT-OUT DEPTH
FRONT OF COUNTERTOP
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
51 mm*
492 mm
COOKTOP
62 mm
Tabla de contenido
loading

Este manual también es adecuado para:

Icbct30i/sIcbct36i/sIcbct30iuIcbct36iu

Tabla de contenido