Elvox 88TK Manual Para El Conexionado Y El Uso página 14

Lector para transpondedor
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
GB
PROGRAMMING
To carry out the programmings remove the reader
protection cover as previously indicated on the
installation instructions.
The board has two push-buttons, P1 and P2,
(as shown in the serigraphy on the printed circuit)
for the programming of the reader functions; the
following are the procedures to make manually a
few programming operations:
-
Transponder key
memory.
-
Transponder key cancellation from the
reader memory.
-
Cancellation of all the keys from the rea-
der memory.
-
Time programming of internal relay.
-
Programming of Id reader device.
For each of such procedures, after about fifteen
seconds, if no operation or pressure of P1 and
P2 push-buttons is carried out, the reader comes
back to stand by position with a short sound
signal.
Transponder key storing in reader memory
Press simultaneously P1 and P2 push-buttons,
wait for three short sound flashings of central
bicolor LED and the switching on of the central
bicolor green LED: with the green LED on, by
means of P2 push-button choose the position of
the key in memory (with each P2 push-button
pressure there is an increase of one position in
memory, where the transponder key will be stored
).
For instance: to memorize a transponder key in
the 2nd position of reader memory press P2 push-
button twice, in a similar way for other memory
positions.
Just after choosing the storing position move the
transponder closer in order to make the reading
and then the storing process (wait for the reco-
gnition by the reader with three acoustic and lumi-
nous signals of central bicolor led); after this ope-
ration the transponder key is stored and, at the
next reading (near the reader), it will be recogni-
zed with the consequent activation of the relay, if
it is set for the activation.
14
All manuals and user guides at all-guides.com
storing in reader
GB
Key transponder cancellation from the reader
memory
Press simultaneously the P1 and P2 buttons, wait
for three short sound flashings of central bicolor
LED and the switching on of the central bicolor
green LED: with the green LED on, press P1
once and, after a sound flashings of the central
bicolor LED, enter the cancellation mode key:
after the red SMD LED switching on, through the
P2 push-button choose in memory the position of
the key where the cancellation has to be carried
out (with each P2 push-button pressure there is
an increase of one position in memory).
For instance: to cancel a transponder key in the
4th position of reader memory press P2 push-
button four times, in a similar way for other
memory positions.
Just after choosing the cancellation position keep
P1 push-button pressed until the central bicolor
red LED switches on: the central bicolor LED will
flash simultaneously 3 times at the activation of
buzzer to indicate the cancellation.
Cancellation of all the keys from the reader
memory
Press simultaneously the P1 and P2 buttons, wait
for three short sound flashings of central bicolor
LED and the switching on of central bicolor green
LED: with the green LED on, press P1 once and
wait for a sound flashing of the central bicolor
LED, press for a second time P1 to enter the
mode of total cancellation of the stored keys: wait
for the flashing switching on of the red SMD LED ,
keep P2 push-button pressed until the central
bicolor LED switches on: the LED will flash simul-
taneously 3 times at the activation of buzzer to
show the cancellation of all the keys stored in the
reader.
Time programming of internal relay
Press simultaneously the P1 and P2 buttons, wait
for three short sounds flashings of central bicolor
LED and the switching on of central bicolor green
LED: with the green LED on, press P1 once and
wait for a sound flashing of the central bicolor
LED, press for a second time P1 and wait for a
sound flashings of the central bicolor LED, press
for a third time P1 and wait for a sound flashings
of the central bicolor LED to enter the mode of
time programming of internal relay: after the swit-
ching on of the green bicolor LED and red SMD
LED, a first pressure of P2 push-button sets up
the internal relay in the bistable mode, further P2
push-button pressures increase of one second for
each pressure the start time of the internal relay
(up to a maximum of 25 sec).
Tabla de contenido
loading

Este manual también es adecuado para:

88tl88tm

Tabla de contenido