. $ % A 7 5 8 % % 9 & D Q Q M T V R ' ' ' ' ' '
Specifying Alarm Input
I
I
I
I
Select "DURATION" and specify a time until the
next alarm input becomes enabled.
• Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M
(S = second, M = minute)
Note: A new detection or an alarm output cannot be performed
until the specified time of duration elapses.
J
J
J
J
Set "MENU" to "BACK" and press the SET
button.
RReturns to the "ALARM IN SETTING" screen.
41
English
All manuals and user guides at all-guides.com
MOTION SETTING
MASKING
OFF
SENSITIVITY
SET
DURATION
5S
PRESET
OFF
MENU
BACK
' ' ' '
K
K
K
K
Select "POLARITY" and specify a polarity for the
signal.
NO : Normal Open (When closed, alarm input is detected.)
NC : Normal Close (When opened, alarm input is detected.)
L
L
L
L
Select "MOTION" and specify the detection logic
of the motion sensor and the alarm input.
OFF : The motion sensor is unused: Detects when an external
sensor responded.
AND : Detects when both the motion sensor and an external
sensor responded. (You cannot select this option when the
"MODE" is specified with "COLOR".)
OR
: Detects when either the motion sensor or an external
sensor responded. (During the "COLOR" mode, detection
is solely dependent on the responsiveness of the motion
sensor.)
Note: While the "SENSE UP" capability is enabled, the motion
sensor does not work. If "SENSE UP" has been set to other
than "OFF", this setting is not available. (See page 28)
ALARM IN SETTING
MODE
ALM
POLARITY
NO
MOTION
OFF
MOTION SET
SET
ZOOM
OFF
ZOOM TIME
5S
DURATION
5S