"Duress" alarm
If the "duress" card is read or the "duress" PIN code is entered
on Zone 1 or Zone 2, the lock will open and, at the same time, the
external alarm will be triggered (if connected). The internal buzzer
will not be triggered.
8. Operating modes
Wiegand card reader
In this mode, the keypad functions as a card reader connected to an
access control device.
Supported orders:
•
Change master PIN
•
Set facility code
•
Card transmission format setting
•
Keypad transmission format setting
•
Optional settings
•
Tamper alarm
Stand-alone access control for a single door
Under this mode, the keypad opens a single door. The door can
be opened by card or PIN or card + PIN. The keypad supports
connecting an external card reader or an access button to exit the
building.
Stand-alone access control for two doors
Under this mode, the keypad can control two doors. Read the card or
input the PIN for Zone 1 and door 1 will open. Read the card or input
19 - User manual