STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner
to tilt properly, which in turn will keep it from draining
properly. To adjust for this, attach a board or piece of
wood to sill. The board or wood piece should have a
depth of at least 1½". Make sure the board or piece of
wood is approximately 1/2" higher than storm window
frame. This will allow air conditioner to tilt enough for
proper drainage. (See Figures 2 and 3)
NOTE: All supporting parts must be secured to
firm wood, masonry or metal.
NOTE: Air conditioner can be installed without
curtains to fit in a narrow window.
NOTE: Electrical outlet must be within reach of
power cord.
Figure 3
1/2"
Minimum
Storm Window
Frame
Storm Window Frame
or Other Obstruction
PRIOR TO INSTALLING THE AIR CONDITIONER
1. Check for anything that could block airflow. Check
the area outside of the window for things such as
shrubs, trees or awnings. Check the inside area to
make sure curtains, drapes or blinds will not prevent
proper airflow.
2. Check the available electrical outlet. The power
supply must be the same as shown on the unit serial
nameplate (located on the left side of the unit). Be
sure outlet is close enough for power cord to reach.
CAUTION! When handling the unit, be careful
to avoid cuts from the sharp metal edges and
aluminum fins on the front and rear coils.
PAGE 3 OF 27
INSTALLATION CONTINUED
Sash
13¼", 14¾"
1½"
Minimum
Minimum
Board or wood
piece must be
approximately
1/2" higher
than storm
window frame
for proper
drainage.
TOP RAIL INSTALLATION
NOTE: Top rail and the side panels are offset to
provide the proper pitch to the rear of 5/16". This
is necessary for proper condensation utilization
and drainage. If you are not using the side
panels, the rear pitch must still be maintained.
1. Attach the top rail onto the top of the outer case
using four short screws. (See Figure 4)
Figure 4
Top Mounting Rail
CURTAIN AND WEATHER
INSULATION BOARD INSTALLATION
NOTE: The weather insulation board adds an
extra layer of insulation to keep air from passing
through the sides of the window air conditioner.
1.
Insert the side curtains into the upper and lower rails
of the air conditioner. Fasten the curtains to the unit
with four short screws. (See Figure 5)
2. Slide the free end of the curtain into the side panel
of the air conditioner. Do this for each side. The
flange for securing the curtain into the window sill
will be facing the room side when installed.
Top Mounting Rail
Figure 5
Flange
Short Screws
Bottom Rail
Flange
0621 IH-7100