Pump Replacement - Little Giant SPK Serie Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE
Refer to
"Replacement Parts" on page 4
while following these instructions. Consult the instruction sheet illustrations for proper assembly and
disassembly of your Little Giant pump. Refer to the pump owner's manual for troubleshooting.

Pump Replacement

1. Disconnect pump from power supply.
2. Disconnect pipe from check valve.
3. Remove cord grommet from the cover.
4. Separate the pump power cord from the grommet.
5. Feed power cord through the cord grommet opening and remove the pump.
6. Remove discharge pipe from pump and install on replacement pump.
7. Install replacement pump into basin.
8. Feed power cord through the cord grommet opening and reinstall cord grommet.
9. Route the pump cord behind the discharge pipe.
10. Remove any cord slack that might potentially interfere with control float or alarm float operation
(if included).
11. Reinstall cover.
12. Reconnect check valve.
13. Connect pump to power supply.
Alarm Switch Replacement
1. Disconnect pump and switch from power supply.
2. Remove cord grommet from cover.
3. Remove all cords from cord grommet.
4. Remove the switch.
5. Install the new switch.
6. Feed the switch cord and the pump cord through the cord grommet opening.
7.
Connect the switch and pump to power supply.
for names and relative location of all components to assist you
MAINTENANCE
Pump Replacement
3
Tabla de contenido
loading

Este manual también es adecuado para:

Spk-6ciaSpk-8cia-1a

Tabla de contenido