PUTTING INTO OPERATION. ADJUSTMENTS
On the first switch-on or after prolonged power losses, the device will remain active for sixty seconds, after which it returns to normal operation.
DETECTION FIELD ADJUSTMENT
The following steps describe detection field adjustment:
Rotate the luminosity selector (LUX) to the "
check coverage.
ADJUSTING LUMINOSITY
The DICROMAT MINI circuit and circuit 1 of the DICROMAT 2 MINI can be adjusted so that they only operate when light conditions are below a
selected level. By rotating the luminosity selector (LUX) to the "
only react under low light conditions DICROMAT 2 MINI .circuit 2 (D1-D2) will always react indepe3ndently of the adjusted luminosity.
For the changes made to take effect in the potentiometers in the adjustment of the equipment, it is necessary to get out from the detection
area and wait for the installation to be turned off.
ADJUSTING THE SWITCH-OFF DELAY
Rotating the time selector (
thirty minutes).
DETECTION INDICATORS
There is a red light inside the sensors that comes on for two seconds when it detects. This LED can be used as an aid in the detection field adjustment
without having to connect the load.

TECHNICAL SPECIFICATIONS

Power supply:
- Circuit 1 (L↓)
Breaking power:
TIME1 (L↓):
Maximum recommended loads
Incandescent lamps
Fluorescent tubes
Low voltage halogen (12 Vac)
Halogen (230 Vac)
Low consumption lamps (CFL)
Low consumption lamps (Downlights)
Led lamps
- Circuit 2 (D1-D2)
Breaking power:
TIME2 (D1-D2):
Own consumption:
- Dicromat MINI:
- Dicromat 2 MINI:
Luminosity range:
Detection angle:
Detection field:
Operating temperature:
Protection type:
Protection class:
Power supply unit
Ceiling from 5 to 20 mm.
LUX L
" position and the time selectors (
) will adjust the switch-off circuits delay, circuit 1(from six seconds to twelve minutes) and circuit 2 (from ten seconds to
230 Vac, 50 Hz
μ 10 A 230 Vac, Cos φ = 1
from 6 s. to 12 min.
2000 W
via contactor
300 VA
1000 W
via contactor
via contactor
via contactor
μ 5 A 230 Vac, Cos φ = 1
from 10 seconds to 30 minutes.
8 VA capacitive (1 W approx.)
10 VA capacitive (1.5 W approx.)
5 – 3000 LUX.
360°.
Up to seven metres diameter to
2.5 metres height.
0°C to +45°C
IP20 in accordance with EN
60529.
II in accordance with EN 60335
under correct installation
conditions
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
2 D1-D2
1 L
) to their minimum positions. Move within the detection field to
" position, it will react under any light conditions. By rotating it to the " " position, it will