Circuit:
V1
Uo
12.6 V
Io
133 mA
Po
1.46 W
Co
1µF
Lo
300µH
Power supply
YPS02-Z.R
II (2) G
[EEx ib] IIC
II (1) D
Power supply
YPS02-X.R
II 2 G
EEx d [ib] IIC T4
II 1 D T135°C
Circuit:
V1
Uo
12.6 V
Io
133 mA
Po
1.46 W
Co
1µF
Lo
300µH
Barrier
YDI02-Z
YDI03-Z
II (2) G
[EEx ib] IIC
Cable: install as stationary
and protected equipment !
Maximum cable length 70m
for a 10-wire standard cable
with a maximum of 200 nF/
km and 1mH/km.
The length of the installed
cable is defined as 20 m
because of the RS-232
specifications.
System appraisal
(see EC-Type Examination Certificate KEMA 02ATEX1108 X):
Co <= 125nF; Lo <= 100µH; Lo/Ro <= 33µH/W
42
V2
V3
V4
12.6 V
8.6 V
12.6V
133 mA
187 mA
150 mA
1.46 W
1.51 W
1.68 W
1µF
4 µF
1 µF
300 µH
300 µH
300 µH
Sartorius cable: type LiYC-Y-CY 4 x 0,5²
(permanently installed on power supply; can be
flexibly installed)
max. Length
= 50 m
max. L
= 8.4 µH
Alternative
Cable
max. C
= 28.2 nF
Connection
Cable
V2
V3
V4
12.6 V
8.6 V
12.6V
133 mA
187 mA
150 mA
1.46 W
1.51 W
1.68 W
1µF
4 µF
1 µF
300 µH
300 µH
300 µH
EX
Written by
Reviewed by
Released by
1)
Circuit:
RS-232
Control signals (only for YDI03-Z)
Uo
12 V
12 V
Io
82 mA
7.5 mA
Po
240 mW
22 mW
Co
1.41 µF
1.41 µF
Lo
5.5 mH
5.5 mH
Lo/Ro
144µH/W
1.5 mH/W
1)
Data output
Uo
8,6 V
Io
23 mA
Po
50 mW
Co
6 µF
Lo
60 mH
Data output
RS-232
(pins A/J/K/N and M)
Ui
12.6 V
Ii
85 mA
Pi
270 mW
Ci
3 nF
Li
0
EX
Written by
Reviewed by
Released by
IIC T4
Circuit:
Ui
Ii
Pi
Ci
Li
FC/FCA/IS......-.X.... /
Date
Name
12.02.02
Klausgrete
12.02.02
Weitemeier
12.02.02
Klausgrete
1)
IIC T4
T-connektor
YTE02-X
Control signals
1)
1)
(pins C/D/E/F/G and M)
Foot
12.6V
10 mA
actuated
30 mW
switch
4 nF
YPE05-X
0
1: per circuit
2: optionally used (passive wiring or switch only)
RS-232 data output with control lines
FC/FCA/IS......-.X.... /
Date
Name
12.02.02
Klausgrete
12.02.02
Weitemeier
12.02.02
Klausgrete
Instrucciones de funcionamiento IS-X
Non hazardous area
Hazardous area
Compact scale
FC......-.X....
FCA......-.X....
Weighing platform
IS......-.X....
II 2 G
EEx ib IIC T4
II 1 D T135°C (optional)
V1
V2
V3
V4
12.6 V
12.6 V
8.6 V
12.6V
133 mA
133 mA
187 mA
150 mA
1.68 W
1.68 W
1.61 W
1.89 W
0
0
300 nF
100 nF
0
0
0
0
Power Supply
Sheet
Verification of the
of
Intrinsic Safety
Rev.
35520-099-61-A4
00
Non hazardous area
Hazardous area
Compact scale
FC......-.X....
2)
FCA......-.X....
Weighing platform
IS......-.X....
II 2 G
EEx ib IIC T4
2)
II 1 D T135°C (optional)
Sheet
Verification of the
of
Intrinsic Safety
Rev.
35520-099-61-A4
00
1
4
2
4
43