Programming - omi ESD Serie Manual Del Operador

Ocultar thumbs Ver también para ESD Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1.
Enter the "FUNCTION MENU" (Push
2.
Select "ALOG" function using
3.
Push
button to display the Alarms Log:
-
-
-
4.
Quit by using the
N.B.: Alarms Log can be erased only with password.
6.6

Programming

The controller's parameters are collected into aggregates, each identified by a label. This allows the user an easy access to the
interested parameters. the label is shown on the display.
On table 6.6.2 are indicated and described all labels and the correspondent programming parameters.
6.6.1 Enter the PARAMETERS MENU and modification of the operation parameters
To ENTER the "parameters menu" proceed as follows:
1.
Push simultaneously for a few seconds
display will show the label of the first parameters family that can be entered.
2.
Using
and
3.
Push
button to show the parameters list contained in the selected family: lower display will show alternately the selected
family label and the code of the first parameter contained, while upper display shows the value of the same parameter.
4.
Using
and
5.
Push
to activate the MODIFICATION of the displayed parameter value.
6.
Increase or decrease the parameter value using
7.
Push
button to save the new value. In the end of the memorize procedure the controller automatically skips on the
parameters list showing the code of the next parameter.
8.
Push
button to return at previous menu.
9.
To QUIT the menu push simultaneously
NOTE: a new set value is memorized also when the outlet is automatic and happens without pushing the confirmation
button.
The CF parameter family can be modified only with the unit in stand-by mode (display shows OFF)
6.6.2 Family Label table
Contained
LABEL
Parameters
ALL
ALL
Shows all
parameters
ST01
ST
ST02
Thermoregulatio
ST05
n parameters
ST06
CF04
CF05
CF06
Cod. 710.0159.01.00 Rev01 – 10.2012
button)
and
.
Lower display will show the code of an alarm.
Upper display will show the progressive number of the same alarm.
Scroll all alarms contained using
button or wait automatically quit.
buttons it's possible to scroll the available parameters family list.
buttons it's possible to scroll through the parameters contained into the selected family.
Summer Set Point
Summer differential
Minimum summer set point
Maximum summer set point
PB1 probe configuration (DEW POINT)
0 = Probe absent
1 = NTC temperature
PB2 probe configuration (AIR INLET / COMPRESSOR OIL PROBE)
0 = Probe absent
1 = NTC air inlet temperature
2 = NTC temperature for compressor oil
PB3 probe configuration (AMBIENT)
0 = Probe absent
5 = NTC temperature
and
.
buttons. The Leds marked with
and
buttons.
buttons or wait 4 minutes without pushing any button (Automatic quit).
Parameters Description
and
start to blink, the upper
STANDARD
udm
Value
0,5
° C
2,5
° C
-1,5
° C
+1,0
° C
1
2
5
13 - 106