[U-12] Remote Control; Rs-232C Remote Control - Mitsubishi Electric LDT462V Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 125
U-12
Remote control
When the monitor is connected directly to a computer using an RS-232C cable (commercially available), the following operations
can be controlled via a communication.
Power ON or OFF
Switching between input signals
Volume control and mute
Auto setup
Check of the internal temperature of the monitor, etc.
NOTE:
For connection with a 25-pin serial port connector on the computer, a conversion adapter (commercially available) is required.
1) Interface
PROTOCOL
RS-232C
BAUD RATE
9600 [bps]
DATA LENGTH
8 [bit]
PARITY BIT
NONE
STOP BIT
1 [bit]
FLOW CONTROL
NONE
For direct connection using RS-232C, use the RXD, TXD, and GND lines.
2) Control command diagram
The command is structured by the address code, function code, data code and end code. The length of the command is
different for each function.
NOTE:
This example shows a basic command that is used when a single computer and a single monitor are connected.
When you want to connect multiple monitors or perform complicated control using other commands than the basic
commands, contact your dealer for advanced command specifi cations.
To send commands with a keypad using terminal software, select "2s" or "30s" for CONTROL TIME OUT in
CONFIGURATION2 in the OSD menu. (Follow the same procedure for LAN control.)
Address code
HEX
ASCII
[Address code]
[Function code]
[Data code]
[End code]
3) Control sequence
(1) A command is sent from the computer to the monitor. (Commands should be sent at intervals of at least 600 ms.)
(2) The monitor sends a return command within 600 ms* after receiving the end code. If the monitor fails to receive the
command, it doesn't send any return command. (*During the power-on/off or input selection process, the transmission of the
return command may take more than 600 ms.)
(3) The computer checks the return command to see whether the command it sent was received or not. The computer must
receive the return command before sending the next command.
(4) The monitor sends various codes other than commands including the return command. While RS-232C control sequence is
in progress, the computer must reject the codes.
Example: Turn the power ON (' ' is for ASCII code)
Control command from
computer
30 30 21 0D
'0' '0' '!' '
'
All manuals and user guides at all-guides.com

RS-232C Remote control

Function code
30h 30h
Function
'0' '0'
Function
30h 30h (ASCII code, '0' '0'), fi xed.
Code unique to each control function.
Data unique to each control function (Not always indicated by numerical values.)
0Dh (ASCII code, '
') fi xed.
Return command from
monitor to computer
30 30 21 0D
'0' '0' '!' '
'
Data code
Data
Data
Description of command
Sending a command for
power-on
Command received
(Command echoed back)
English-38
Carry out as necessary
End code
0Dh
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bli09

Tabla de contenido