Grohe Ondus 36 056 Manual De Instrucciones página 4

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Applications
Faucet for use with concealed mounting set 36 068
in conjunction with function unit 36 072.
Specifications
• Max. flow
- Spout
approx. 20 L/min or 5.3 gpm/60psi
- Handshower
approx. 9.3 L/min or 2.5 gpm/60psi
• Automatic safety shut-off (factory setting):
• Safety stop (factory setting):
• Type of protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Note:
Installation of backflow protection must comply with local
codes and regulations.
Installation
Refer to the dimensional drawing on fold-out page I.
I. Faucet, see fold-out page II, figs. [1] to [3].
1. Insert adapter tube (A) with mounting set (B) from below and
attach escutcheon (C), see fig. [1].
1. Observe the correct installation position!
2. Tighten adapter tube (A) using faucet key (D), see fig. [2].
3. Fasten connection nipple (E) with clamp (E1) and connect
hose (F).
4. Screw in adapter (G) and insert decorative trim (H) in
escutcheon (C), see fig. [3].
5. Fit spout (J) and fasten with set screw (K).
6. Insert plug (K1).
II. Hand shower, see fold-out page II, figs. [4] and [5].
1. Insert hand shower holder (L), screw on mounting set (M)
and fasten using faucet tool (L1), see fig. [4].
2. Connect shower hose (N) to hose (O), see fig. [5].
3. Fit escutcheon (P), see detail. Screw in bracket (Q) securely
by hand.
4. Feed through shower hose (M) from below and screw on
taper nut (R1).
5. Install hand shower (R).
III. Wall adapter, see fold-out page II, figs. [6] to [9].
1. Cut faucet template (S) to length, see fig. [6].
2. Guide plug-in connector (T) through wall adapter (U), see
fig. [7].
3. Insert wall adapter (U) and turn through 45°, see fig. [8].
The faucet depth of wall adapter (U) can be adapted to the
wall thickness by turning the internal screws (U1).
4. Align wall adapter (U) and tighten internal screws (U1), see
fig. [9].
1
English
30 min
102 °F
- Faucet
IP 54
- Operating panel
IP 57
B
2
2500 V
212 °F
IV. Operating panel, see fold-out page II, figs. [10] and [11].
1. Attach connector (T) to connector (V1) of operating
panel (V) and push back into the concealed faucet body, see
fig. [10].
2. Insert operating panel (V) in wall adapter (U).
3. Fasten operating panel (V) using set screws (W), see
fig. [11].
Open cold and hot-water supply and check connections
for water-tightness.
Operation
Using the operating panel
Start/Stop Button
Operational readiness of faucet. Water flow
commences following actuation of a programme
button. Repeated actuation stops water flow.
The connected outlets can be operated
simultaneously.
Pause button
Interrupts the flow of water (temperature arrow on
operating panel orange). The flow is resumed by
pressing the button again.
The faucet switches off automatically after a preset
time in pause mode (factory setting 60 s).
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
The display flashes until the preset temperature
is reached.
Volume
Increases
or decreases the flow rate in a total
of eight stages.
Temperature safety button
Overriding the safety stop (factory setting: 102 °F).
The actual value is synchronised with the display at 100 °F.
See Calibrate in the section Setting mode.
Programme buttons
Drench shower head
Head shower
Side shower
Hand shower
Bath inlet
Memory button 1
Memory button 2
Tabla de contenido
loading

Tabla de contenido