Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter blue
marked copper pipe.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Rate of flow:
The product is exclusively designed for drinking water!
Highest possible water pressure at
user's site in Mpa
0,1 - 0,15
0,2 - 0,3
0,4 - 0,7
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
max. 5 l/min
Table for the throttle hose lengths to be used
8, 10 and 15 liters
without throttle hose
Throttle hose shortened to 90 mm
Cause
- Spray former calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
Assembly see page 10
Symbol description
Do not use silicone containing acetic acid!
Cleaning
see enclosed brochure.
Dimensions (see page 12)
Operation (see page 14)
When the storage tank is being heated, the
spout will drip.
Spare parts(see page 13)
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Special accessories (order as an
extra)
special tool #58085000
Installation putty
Test certificate (see page 14)
Device content
Throttle hose shortened to 90 mm
Throttle hose unchanged
Adjust flow volume at corner valve
Remedy
- Clean spray former, exchanging if
necessary
- Exchange cartridge
- Exchange cartridge
up to 5 liters
Throttle hose unchanged