Setting The Dip Switch - Dometic GROUP Waeco PerfectCharge CA360 Instrucciones De Montaje

Ocultar thumbs Ver también para Waeco PerfectCharge CA360:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
All manuals and user guides at all-guides.com
Perfect Charge CA360
6.3

Setting the DIP switch

You can adjust the device using the DIP switch. S1 and S2 set various charg-
ing graphs. S3 activates or deactivates the temperature compensation of the
charging voltage.
S4 regulates the fan function. If S4 is at "On", the fan remains switched off
and the output of the device is controlled depending on the housing temper-
ature. If the device reaches the temperature limit, the current drops to approx.
80%.
➤ Set the DIP switch according to your requirements and the following table.
S1
S2
S3
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off
On
IBS = battery sensor
6.4
Connecting the fault display relay
If an alarm occurs, the (common) alarm contact switches to the normally
open contact.
➤ Connect the relay to the fault display on the alarm contact according to
the following table (fig. 1 7, page 3).
Contact in
fig. 6, page 5
1
2
3
EN
Charging
Charging
voltage 1
voltage 2
IBS setting
13.8 V
IBS setting
13.8 V
14.4 V
13.8 V
14.4 V
13.8 V
14.7 V
13.8 V
14.7 V
13.8 V
Allocation
NC (Normally Closed): normally closed contact
COM (Common): common contact
NO (Normally Open): normally open contact
Installing the device
Voltage
Current
sensing
sensing
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Tempera-
ture com-
pensation
with IBS
No
with IBS
No
with IBS
No
39
Tabla de contenido
loading

Tabla de contenido