4 - CONTROL UNIT
•
Flasher control with/without integrated intermittency function
•
Integrated management for electric locks 12V max. 15VA or
settable to 24V with dedicated programming. This output can
also be used to control courtesy lights
•
Inputs for start, stop and pedestrian opening wired
commands, customisable to open, stop and close
•
Double input for safety devices: "PHO1" during closing and
"PHO2" during closing and/or opening
•
Possibility of powering 24VDC accessories
•
Input for gate status pilot light signalling the position of the
leaves
•
Input for external antenna that can be used for increasing the
range of the transmitters
•
Pause time for automatic re-closing adjustable to between 0
and 180 sec. with trimmer
•
Obstacle sensitivity adjustment with trimmer
•
Motor force adjustment with trimmer
•
Incorporated radio receiver (433.92MHz), compatible with V2
rolling transmitters
•
6 signalling LEDs (Paragraph 7).
•
Slow-speed opening and closing (customisable through
dedicated programming).
5. CONTROL UNIT SETTING
5.1 - TRIMMER ADJUSTMENT
POWER: adjustment of motor power. Turning the trimmer
clockwise increases the motor's power.
To validate the modification it is necessary to programme the gate
path.
OBS: Obstacle, sensitivity to obstacles: adjustment of the obstacle
detection function. Turning the trimmer clockwise increases the
drive time before obstacle detection (less sensitivity). Therefore, in
systems with particularly unfavourable mechanical conditions, it is
advisable to keep the drive time high.
PAUSE: Pause time before automatic gate closing. Turning
the trimmer clockwise increases the pause time from 0 to 180
seconds. Please note: the AUTO dip-switch must be put to ON.
DELAY: NOT USED
m
Varying the "POWER" trimmer has no effect until the
stroke is reprogrammed (par. 8).
5.2 - DIP-SWITCH ADJUSTMENT
DIP
DESCRIPTION OF OPERATION
m
DIP 1-2
OFF ON
MOTOR
DIP 3
ON
Step-by-step command mode: Open /
STEP
Stop / Close / Stop
At every start pulse (wired or via
transmitter), the control unit performs an
action. Starts the motor if the automation
system is stopped, and stops it if it is
moving.
OFF
Condominium mode
The control unit only accepts commands
(either wired or via transmitter) for the
opening phase.
Starts again from zero with the set delay
when the automation system is open.
With the automation in the opening
phase, it continues to open, and with the
system in the closing phase it reopens
fully.
The automation can re-close with the
time set through the "PAUSE" trimmer,
if the "AUTO" dip-switch is set to ON.
If not, it is necessary to give a START
command (either wired or via transmitter)
with the automation fully open.
DIP 4
ON
Automatic closing activated (time set with
AUTO
the "Pause" trimmer)
OFF
Automatic closing deactivated
DIP 5
ON
Safety devices connected to "PHO2" set
PHO2
as photocells (movement stopped during
opening and closing)
OFF
Safety devices connected to "PHO2" set
as edges (reverse of opening movement)
DIP 6
ON
Intermittent power supply for the flashing
HAZ
light
OFF
Fixed power supply for the flashing light
DIP 7
ON
Immediate re-closing after intervention of
FAST
"PHO1" photocells
OFF
No intervention of the photocells during
re-closing
DIP 8
ON
Reverse opening direction (the system
FUNC
must be programmed afterwards)
OFF
Reverse opening direction (the system
must be programmed afterwards)
- 31 -
do not change the DIP setting