5.18 Switching off for lengthy periods
If the EXCLUSIVE boiler is not used for a long time, the following operations
must be carried out:
- set the status of the boiler to OFF
- set the system's main switch to "off"
- close the fuel and water taps of the heating and domestic hot water
system.
In this case, the anti-freeze and anti-blocking systems are deactivated.
Drain the heating and domestic water system if there is any risk of freezing.
HOT WATER ONLY
HEATING AND HOT WATER
Closing
position
5.19 System reset
b
This operation must be carried out only by professionally qualified
personnel.
Whenever necessary, it is possible to restore the factory settings by
carrying out a SYSTEM RESET:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select INSTALLATION with the "up" and "down" keys, confirming the
selection
INSTALLATION
WEATHER COMPENSATION
THERMOREGULATION
RANGE RATED
CALIBRATION
INSTALLER
INSTALLER
- select SYSTEM RESET with the "up" and "down" keys, confirming the
selection
INSTALLATION
ZONES MANAGER
ZONES MANAGER
SENSOR CALIBRATION
SENSOR CALIBRATION
SYSTEM RESET
INSTALLER
INSTALLER
BOILER
BOILER
OFF
OFF
SUMMER
WINTER
TECHNICAL
TECHNICAL
INSTALLATION
PARAMETERS
PARAMETERS
RANGE RATED
CALIBRATION
SYSTEM RESET
- select CONFIRM to conform the system reset or else CANCEL to cancel
the operation.
Note: after a reset it is necessary to carry out a new configuration of the
system; for details about this procedure, see the following section.
5.20 System configuration
b
This operation must be carried out only by professionally qualified
personnel.
When restarting after a replacement of the REC10 rather than after a
"SYSTEM RESET", the remote control displays an initial screen with
the firmware revision. Pressing "ok" a guided procedure is started for
configuring the system; select the desired options with the "up" and "down"
keys, confirming the selections made:
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY TO
PRESS ANY KEY
TO CONTINUE
- LANGUAGE selection:
ENGLISH
- setting TIME & DATE
TIME & DATE
ENTER TIME AND DATE
ENTER TIME AND DATE
12
18 / 11 / 2013
USE THE ARROWS TO MODIFY
USE THE ARROWS TO MODIFY
- setting the operating mode of the REC10:
MASTER: select this option when the REC10 is also a MACHINE
INTERFACE.
- configuration selection:
FROM AKM: to reset the current boiler configuration on REC10 MASTER
and finish the operatione
NEW: to set a new system configuration restoring the factory setting of
the parameters
CONFIRM
CONFIRM
CANCEL
CANCEL
CONTINUE
TIME & DATE
:
17
ENGLISH