TECHNICAL DATA
Contol unit supply
Operating temperature
Time of work
Output supply
Power maximum motor
Protection level
Radio receiver
1) DESCRIPTION
The CL.MC control unit is able to control 1 electromechanical tubular motor for electric sun shade curtains
and rolling shutters.
2) ACCESSORIES
The control unit can be equipped with the following accessories:
T4WV-C: 4-channel, rolling code transmitter.
3) WIRE DIAGRAM
Terminal
Function
1,2
Phase, Neutral
3,4,5
Motor control
6
CLOSE push button
7
OPEN push button
8
Push buttons, common
RADIO
Integrated radio module
4) OPERATION
To control the motor, use auto-default push buttons or buttons of the stable type.
Operation of push buttons: if the buttons are pressed for one second, the sun shade curtain moves in
the required direction until it reaches the end of stroke set by the motor limit switch. If the stroke must be
stopped before time, press the button corresponding to the reverse movement direction.
Transmitter operation:
Button1 = CLOSE / Button3 = OPEN. If the stroke must be stopped before time, press the button corre-
sponding to the reverse movement direction.
5) PROGRAMMING FROM P1 PUSH BUTTON
Press push button P1 and keep it pressed for at least 3 seconds. When P1 is pressed, the buzzer will send a
continuous sound, 1 second long. If P1 is kept pressed for more than 3 seconds, the buzzer will then send a
continuous sound, 5 second long. During this period of time, press the key of the transmitter to be stored in
memory. If the code memorization is successful, an intermittent buzz sound will be heard.
If the P1 button is NOT kept pressed for more than one second, the receiver switches to standard mode
again.
Only the first transmitter code can be programmed by pressing the push-button. For the programming of the
other transmitter codes, please refer to paragraph 6: "How To Programme From Transmitter".
All manuals and user guides at all-guides.com
230 Vac
-10°C / +60°C
2 minutes
1 motor 230 Vac
300W
IPXX
433,92 MHz integrated
CL.MD CONTROL UNIT
Description
Control unit power supply, 230VAC 50Hz
Motor opening/closing controls:
- Close(3): CLOSE contact;
- COM(4): command, common;
- Open(5): OPEN contact.
Connection for closing push button
Connection for opening push button
Opening and closing push buttons, common
Receiver, 433.92 MHz