ADJUSTING THE SIPHON TUBE FOR SMALLER BOTTLES
1. Your new water cooler features an adjustable quick-connect system. For proper operation, make sure the
connector is sealed tightly. (Fig. 1)
2. The connector can be removed easily for cleaning with warm soapy water. (Fig. 2)
3. The stainless-steel siphon tube can be adjusted up or down to accommodate a 3-gallon to 5-gallon
water bottle. (Fig. 3)
Fig. 1
OPERATION
After the water bottle has been connected to the water cooler, the unit is ready for use. Turn the power
switch on the back of the unit to ON. The water cooler will start running. First the unit will pump the water
from the water bottle into the cooling and hot tanks, and then the unit's compressor will start to operate.
Press the hot faucet to fill the hot tank. Once water flows from the hot faucet, the red hot tank switch
found on back of the unit can be switched to ON. The first time the water cooler is used, you will have to
wait at least one hour for cold water and 15 minutes for hot water.
The water cooler has 3 indicator lights on the front panel.
•
When the
indicator light is on, the water cooler is heating water inside the heated water tank.
•
When the
indicator light is on, there is no water left in the water bottle and it needs to be
replaced. Replace the water bottle, and close the door to reset the unit. The water cooler will work
again and the indicator light will turn off.
•
When the
indicator light is on, the unit is in the process of cooling water inside the cooling tank.
Using the Water Cooler
•
To dispense HOT water, slide the red safety lock to the left and press the button all the way down.
•
To dispense COLD water, press the cold water button all the way down.
•
To dispense ROOM TEMPERATURE water, press the room temp button all the way down.
Fig. 2
Fig. 3
HEATING
EMPTY
COOLING
5