Emerson MVS205 Manual Del Usuario página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Safe Use Instructions — MVS205
MVS205 Multi-Variable Sensor
Use this safe use instructions (SUI) document with
conjunction with the following device-specific
manuals:
ROC800-Series Remote Operations Controller
Instruction Manual (part D301217X012)
ROCLINK™ 800 Configuration Software User
Manual (for ROC800-Series) (part
D301250X012)
FloBoss™ 107 Flow Manager Instruction Manual
(part D301232X012)
ROCLINK 800 Configuration Software User
Manual (for FloBoss 107) (part D301249X012)
FloBoss 103 and 104 Flow Manager Instruction
Manual (part D301153X012)
ROCLINK 800 Configuration Software User
Manual (for FB100-Series) (part D301159X012)
For full cautions and descriptions of installation
and troubleshooting procedures, refer to those
manuals.
This SUI describes the MVS205R, the remote
version of the MVS205 Multi-Variable Sensor. All
references to MVS205 in this SUI are to the Model
MVS205R.
MVS205 Special Conditions for Safe Use:
The device contains a thin wall diaphragm.
During installation, maintenance, and use
take into account the environmental
conditions to which the diaphragm is
subjected. Follow in detail the manufacturer's
instructions for installation and maintenance
to assure safety during the device's expected
lifetime.
Ensure that threaded covers have, at a
minimum, 8 full threads engaged.
Remote Automation Solutions
Website: www.EmersonProcess.com/Remote
Figure 1. Label on the MVS205 Multi-Variable Sensor
CAUTION
When installing units in a hazardous area,
make sure all installation components selected
are labeled for use in such areas. Perform
installation and maintenance only when the
area is known to be non-hazardous.
Installation in a hazardous area could result in
personal injury or property damage.
CAUTION
Always turn off the power to the sensor before
you attempt any type of wiring. Wiring of
powered equipment could result in personal
injury or property damage.
Disconnect power from the ROC or FloBoss
unit before installing or removing from service
the MVS205 sensor to avoid damage to the
sensor.
Do not reverse polarity of the power wires (+
and —) while wiring the Remote MVS units, or
circuits in the Remote MVS and elsewhere may
be damaged. Double-check for proper
connections before applying power.
To avoid circuit damage when working inside
the unit, use appropriate electrostatic
discharge precautions, such as wearing a
grounded wrist strap.
Do not exceed the maximum differential and
static pressure ranges listed on the label of the
MVS205 sensor.
Part D301205X012
September 2015
Tabla de contenido
loading

Tabla de contenido