π
H-5647
STAINLESS STEEL
ROTARY DRUM PUMP
TOOLS NEEDED
1/2" Wrench
IMPORTANT! This pump is made out of 304 stainless steel and PTFE. Use liquids compatible with pump
component materials. Follow OSHA guidelines when using this pump, including proper grounding and
protective gear as required. For a full list of materials and compatible chemicals, see uline.com.
Unit not UL or FM approved.
1.
Rotate handle clockwise several times to prime. If
unit does not prime after a few turns, pouring some
fluid into pump inlet may help free pump.
2. For siphoning, position handle straight down.
3. To stop siphoning, rotate handle 1/4 turn (leave
handle in horizontal position).
PAGE 1 OF 6
1-800-295-5510
uline.com
Flathead Screwdriver
SPECIFICATIONS
Pump Type
Flow
Maximum Fluid Temperature
Bung Adapter
Suction Tube Length
Inlet
Outlet
Wetted Parts
Maximum Viscosity
OPERATING INSTRUCTIONS
Rotary – Vane
10 GPM
140°F / 60°C
2" Male
40" Maximum
1⁄" O.D.
1" O.D. Curved Spout
304 Stainless Steel, PTFE
1,000 cps
4. After using pump, position handle straight down.
Liquid will drain back into the container.
5. If pump is removed from drum, rinse it thoroughly in
a liquid that is compatible with both the pump and
the fluid being pumped.
6. Regularly check pump and suction tubes for leaks.
Leaks in the suction line or in pump housing will
cause inefficient pumping and loss of prime.
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
0721 IH-5647